Remote test of the detector functionality including the detector vibration sensor eleme
the acoustical fixing to the protected object. This test alternative incorporates the Test
transmitter SC113 to be mounted on the protected object but covered by Detector SC10
Remote range test of several Detector SC105s simultaneously. This test alternative
includes remote test of the detector function
element and the acoustical fixing to the protected object as well as testing of the signal
propagation in the solid structure of the protected object betw
External Test Trans
mitter SC115.
J1 (see
Figure 7-1 Function modules on Detector Base
for remote test, and detai
l functions a
Table 9-1 Remote Test
Position
Functio
No test
Range test
1
External Test
Transmitter
SC115
(including
mounting check)
1-2
Electronics test
Complete t
with Test
Transmitter
2-3
SC113
(including
mounting check)
* Factory default settings are shown in grey.
ality including the detector vibration sensor
on page 13) on the detector base is used
re sho
wn in the
table below.
n
Method
Connect jumper to J1 pin 1
only (or no jumper at all).
with
See
"External Test Transmitter SC115 User
Connect jumper to J1 pin 1
and 2;
Apply an active low 0 volt to
terminal 10 on the terminal
block to start the test.
Connect Test Transmitter
est
SC113 to J1(red cable to
pin 2 and black cable to pin
3);
Apply an active low 0 volt to
terminal 10 on the terminal
block to start the test.
Honeywell
nt and
een Detector SC105 and the
R
esult
Guide".
A successful remote test
will be acknowledged by an
alarm from the detector
within 1 second.
A successful remo
te test
including mounting check
will be acknowledged by an
alarm from the detector
within 1 second.