ABB AquaMaster Explorer Instruction Manual page 36

Electromagnetic flowmeter
Hide thumbs Also See for AquaMaster Explorer:
Table of Contents

Advertisement

Electromagnetic Flowmeter
AquaMaster™ Explorer
Wetted Materials
Screw-end meters
Brass
Flanged meters
Electrodes – stainless steel 316L
Lining
Suitable for potable water (UKWFBS listed)
Pressure limitations
As flange rating or 20 bar (290psi), whichever is the lower
Pressure equipment directive 97/23/EC
This product is applicable in networks for the supply, distribution and discharge of water and associated equipment and
is therefore exempt.
Conductivity
>50 µS/cm
End Connections
Thread-end connections
3
3
15 mm – G
/
in B
/
4
4
20 mm – G 1 in B 1 in NPSM
1
25 mm – G 1
/
in B 1
4
40 to 300 mm (1.5 to 12 in) flanged
EN1092-1 / ISO 7005 – PN10, PN16, PN25, PN40
ANSI B16.5 1.5 Class 150
AS 2129 Tables C, D, E, F and H
AS 4087 PN14, PN16
JIS to BS2210, 5k, 7k5, 10k
350 to 600 mm (14 to 24 in) flanged
EN1092-1 / ISO 7005 – PN10, PN16, PN25
AS 4087 PN14, PN16
AS 2129 Tables C, D, E, F and H
34
in NPSM
1
/
in NPSM
4
5 Specification
IM/AM/E Issue 10