Electromagnetic Flowmeter
AquaMaster™ Explorer
Logger details (option)
Logger Function
No. of Records
Logging Interval
Typical Capacity
Mode
Use ABB LogMaster
Use Technolog (PMAC)
Use Primayer
Primeware
Use OSI PI Database /
CBV (WADIS) System
GSM Antenna (option)
Mounting
Integral with transmitter or remote.
Antenna environmental
IP66 (NEMA4) waterproof for accidental submersion
(Note. The GSM does not operate with integral antenna under water).
General advice is to mount the antenna as high as possible, always outside of any metal enclosure and not under the
surface of the ground.
IM/AM/E Issue 10
1
Flow & Pressure
8831
15 to 65500 s (adjustable)
3 months @15 min
Cyclic
Logger
2
Flow & Pressure
11361
~7 days @ 1 min
Cyclic
5 Specification
3
Forward, Reverse, Tariffs
& Net Flow Totals
366
24 hr (fixed)
1 year
Cyclic
39