HDL-MPT4-RF.18
Remark:
Remark the channel for the easy management.
Load Type:
Select the corresponding load type for each channel according to the real situation; it is
just like a remark, would not affect the behavior of lamps. Default selection – Undefined.
Lower Limit:
If setup the lower limit for the channel, when dimming to this value, the output is 0.
The Lower limit is useful if you unfortunately have some lamps which produce unstable
(trembling) light when dimming in low segment. You can bypass the unstable segment by
setting a suitable Lower limit.
Max Level:
The max output brightness of a channel.
For channel1, if the connected load is bulb, the max value cannot exceed 80%; if the
connected load is LED, the max value must be small (less than 80%, user needs to test
the proper value themselves), otherwise power interface cannot supply enough power,
then lead to dimming flicker, more serious, the power interface will automatically restart.
If the connected load is LED, and its power is less than 30W, must connect the constant
current module in parallel, the max value can up to 80%.
Test Level, On/Off:
Input the test level, check the 'On/Off' box to turn on the channel, un-check to turn off it.
It's used to test the loads after installation.