Static Generator Values 125-200 Exc (Kokusan 2K-3) - KTM 125 Repair Manual

Hide thumbs Also See for 125:
Table of Contents

Advertisement

STATIC GENERATOR VALUES 125-200 EXC (KOKUSAN 2K-3)

Measuring conditions:
– cold engine
– seat and tank removed
– all connectors and the ground connection in a non-corroding condition, connectors tightly connected
– light switch turned off
– kick the kick starter forcefully at least 5 times for each measurement
7
8
10
Check the generator output
page) for voltage between the following cable colors:
– between yellow and brown (ground), connector
– between white and brown (ground), connector
– Repeat both measurements with connector
measured values should be the same.
NOTE: the black measuring lead of the peak voltage adapter must be
applied to the ground.
Check regulator rectifier output voltage
opposite page) cable colors yellow/red, regulator rectifier
bl
capacitor
– between yellow/red and brown (ground)
NOTE: the black measuring lead
applied to the ground.
S
6
(also see circuit diagram on opposite
Multimeter display: 19 volts +/- 2 volts
Multimeter display: 24 volts +/- 2 volts
disconnected:
Multimeter display: 14 volts +/- 1 volt
S
of the peak voltage adapter must be
7-7C
7
disconnected
8
disconnected
7
8
and
connected. The
9
(also see circuit diagram on
bk
connected,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200