 No block valve should be installed in the steam pipelines. Strictly no blocked or blended pipe,
otherwise have negative affect on the flow of steam and condensate. The steam pipelines should
be installed with a slight angle so that the condensate can flow back to the generator or the
nozzle.
 Steam generator should be installed indoors to prevent icing. The generator should be installed
and leveled with the arrow pointing upward at an easy-access place, otherwise do not switch on.
 The steam pipeline must be copper pipes, all other material such as plastic, acrylic should not be
used since they cannot endure 302℉ or higher temperature.
 All inlet and apertures should be sealed to prevent any leakage of steam and protect the
generator and customers.
 Draining water directly to the steam room from the water tank may cause serious scald and
damage the steam room. A separate draining pipe is required to drain water to the drainage.
All inlet water pipes and steam pipelines should be built according to the National Standard
(refer to Figure 7) and this should be done before sealing the wall.
First connect the water magnetizer (if applicable) to the water inlet solenoid valve.
Water inlet:
Then please use a 1/2‟‟ flexible stainless steel hose to connect the other side of the water magnetizer
and the water supply pipeline. Do not connect to metal water supply pipeline directly which may
damage the water inlet valve. Only use cold water supply.
Use no less than 1/2‟‟ copper pipe to connect the steam jet and the steam outlet pipe
Steam outlet:
of the generator. The pipe should be less than 10 ft long and minimize the number of elbows,
otherwise heat isolating methods should be implemented.
The steam nozzle should be about 1 ft from the ground and at least 6" from customer
Steam nozzle:
seats. All nozzle should face downwards. Put the decorating cover onto the outlet pipe and firmly
seal with glue then screw on the nozzle. Do not screw too hard and break the cover and nozzle.
8