Caution:
The control wire and temperature wire should not be parallel to or intersect with the
power wire. The temperature sensor should not be installed on the side of the wall which is behind
the door when the door is opened and the controller should not be installed in any moist place.
Install in the roof
Install in the closet
4. Installation of pipeline
Caution:
 If the generator is installed at a place where difficult for customer access, the water inlet valve
must be easy to access for emergencies.
 The maximum water pressure for electromagnetic valve is 30psi. To protect the electromagnetic
valve from extremely high water pressure, please turn down the inlet slightly or install water
pressure relieving valve.
 Do not install saddle-backed or needle valves on the inlet. Please dredge and clean the pipe
before installation.
Suitable
for installation
Install under
the washing basin
Install in the basement
Figure 4
SENSOR WIRE
CONTROL WIRE
CONDUIT
SENSOR WIRE
CONNECTOR 2P
CONTROL WIRE
CONNECTOR 6P
TEMP SENSOR
WALL
IMMOBILIZING PLATE
IMMOBILIZING SCREW
Figure 6
T E M P S E N S O R W I R E
SEALING GLUE
CONTROLLER
D O U B L E
S I D E D
A D H E S I V E
WALL
Figure 5
7