5. Electrical installation
Caution:
All electrical should be installed by licensed electricians and conform to local and national
codes.
Power supply must be cut off before installation, maintenance and repair. Press the on/off button
on the generator cannot cut power from the supply.
No additional power supply or wire is allowed to connect to the generator. Do not connect the
ground wire to the neutral wire.
Only the original parts and elements from our factory are allowed to be used in installation,
operation, maintenance and repair.
After the installation of the pipeline and electrical circuits, careful checking must be performed
before switch on the generator.
The generator has been carefully installed, checked and tested in factory, thus customer only
need to install the power wire and control wire.
INSTALLATION OF CONTROL WIRE
Take off the service cover of the generator, pull the control wire at the back of the controller
through a conduit and then insert it into the hole at the back of the generator case and connect to
the plug on the circuit board. (Refer to figure 8).
INSTALLATION OF POWER WIRE
Caution:
The power supply should be 240VAC,60Hz, please refer to the nameplate of the generator or
table1 of this manual.
Flexible
stainless
steel
hose
Figure 7
9