Manual Filter Flush - Netafim nmc-pro User Manual

Hide thumbs Also See for nmc-pro:
Table of Contents

Advertisement

MANUAL MENU
3.4
M anual Filter Flush
2 7 B
Use this screen to activate manual filter flush. Us this function only when the system is irrigating.
2. Manual
MANUAL FILTER FLUSHING
Which Filter
<None>
All Filters
Filter 01
Filter 02
Yes
Note: "All Filters" means all filters; however one only one filter is flushed at a time.
Note: Filter flush process can start only after main water line is full. Default time is one minute as shown in picture
below (see Menu 3.3).
4. Filter Flush
<None>
Menu
Hot Screen 5 to view
flushing status
ALARM DEFINITION
Water Fill Up (min)
Water Leak (m3)
Water Leak Period (hh:mm)
Identify Leak-Subtr. Meter? 
Dosing Channel Leak Delay(s)
Dosing Channel Leak (Pulse)
Dosing Flow Difference (%)
Missing Pulses For No Flow
Stop System Cons.Flow Alarms
# of Irrig. Without Drainage
Select filters (usually all)
MANUAL FILTER FLUSHING
Which Filter to Flush?
FILTER FLUSHING STATUS
Item
Flush Status
Time To Nest Flush
Delta Pressure (Digital)
Flushing Filter No.
Remaining Filters Qty.
Flush Time
Current Delta Pressure
Main Filter Delay
1
1.000
00:30
NO
3
10
25
10
--
3
All Filters
ON
--:--:--
OFF
1
1
00:07
----
00:00:00
NMC-PRO