Underpressure caused by a switched-
on circulating air fan! The Combi furnace can
cause malfunctions in other gas devices in the
same installation space! Install the Combi fur-
nace in its own compartment.
Make sure that the installation space fulfills the
following requirements:
• DO NOT install the Combi furnace in the
same space with a heating device that re-
quires room air.
• The opening for the circulated air intake
(RV's interior, installation space) must be at
least 23 ¼ in.² (150 cm²) free cross section.
• Service technicians must be able to readily
access as well as easily remove and re-install
the Combi furnace and the exhaust tube.
– This applies to items such as service hatch-
es and cabinet doors.
– Truma recommends a seating dinette, clos-
et or under-bed location.
• The Combi furnace must be mounted on a
flat surface. It may not be mounted on a wall
or in an inverted mounted position.
• It must be possible to access the switch for
the gas shut-off valve (see Fig. 2 – 4).
• Comply with the permissible length of
tube for the exhaust venting system;
see"Permissible length of exhaust venting
system" on page 11.
• Install the wall cowl in the proper place;
see"Installation position: wall cowl" on
page 11.
• Ensure that there is enough space for the
warm air ducts and insulating sleeves;
see"Warm air distribution" on page 15.
• Truma recommends installing the Combi
furnace in the middle area of the RV. This al-
lows the air to be distributed evenly through-
out the vehicle.
• Make sure that no combustible material can
fall on the Combi furnace.
8

Dimensions and clearances

Dimensions
Example: Furnace installed in direction of mo-
tion without front panel (not to scale).
b
1
2
b
Fig. 4a
1 Cover plate
2 Sturdy ledge (wood slat or equivalent)
(minimum of 1 ¼ in. x 2 in. (32 x 50 mm))
3 Profiled strip (or equivalent)
4 Exterior wall of RV
See Fig. 4a for the minimum installation
dimensions.
Dimension
inches
a
23.8
a *
)
21.9
b
19.5
c
1.25
d
7.1
e
13.8
*)
Minimum distance, if gas connection is
not inside the installation compartment or
if the compartment around the gas con-
nection is open
4
Direction
of
motion
2 3
TOP VIEW
FRONT VIEW
mm
605
555
495
32
180
350