Truma Combi D comfort plus Diesel furnace with supplementary indirect water heating FIRE OR EXPLOSION HAZARD Operating instructions Failure to follow safety warnings exactly To be kept in the vehicle. could result in serious injury, death or prop- This document is part of the product.
SAVE THESE INSTRUCTIONS ..........6 Combi D below. Safety symbols and signal words ........6 Safety behavior and practices ..........6 Truma CP plus referred to as CP plus below. Safety features ..............8 Operating Instructions Intended use How the Combi D furnace works ........9 The Combi D furnace with supplementary indi-...
Room temperature sensor and combustion air intake CP plus control panel Insulating sleeve Opening for circulation air intake Truma water pressure regulator (with mounted grid) Non-return valve Warm air ducts Truma pressure relief/drain valve Warm air end outlet with air throttle...
Consumer Safety Information • Keep the area in front of the warm air outlets (Fig. 1–L) free of combustible or heat-sensi- tive materials. Do not put any material into SAVE THESE INSTRUCTIONS the warm air outlets. • In order to avoid overheating of the Combi D Safety symbols and signal words furnace, keep the air inlets of the Combi D furnace (Fig.
Page 7
• The exhaust gas system must be inspected • How long before hot water causes skin by an expert at regular intervals or at least damage? every 2 years. • Fuel at low temperatures: Temperature Time before skin becomes Refineries or filling stations automatically °F (°C) scalded adapt the fuel to the usual winter tempera-...
Safety features Safe handling of malfunctions • Switch OFF the Combi D furnace if anything seems to be out of the ordinary. The Combi D furnace is equipped with the following safety devices: • Danger of fire or explosion when attempting to use a flood-damaged Flame monitoring Combi D furnace or if the RV has been in- If the flame goes out, the fuel supply is...
Operating Instructions A wall cowl allows combustion air to flow into the furnace and exhaust gas to flow out. The wall cowl and the furnace are connected by a Read and follow the “Consumer Safety In- duct in the duct exhaust venting system: an ex- formation”...
– The pressure relief/drain valve is not ser- viceable; if defective, it must be replaced. It must be replaced by a certified service technician. – It must only be replaced by the Truma pressure relief/drain valve rated for 65.25 psi (4.5 bar) which is CSA certified and registered.
Inspections before each use Check the Combi D furnace for the following points before each use. In case of damage, con- tact an authorized Truma service provider and do not operate the Combi D furnace. • Inspect the furnace (Fig. 1–G), exhaust vent- ing system, and wall cowl (Fig.
1. Close the pressure relief/drain valve, if open • Test the temperature of the water before (refer to “Closing the Truma pressure relief/ placing a child in the bath or shower. drain valve” on page 11).
3. Open all water release points, e.g. cold and hot water faucets, showers, toilets. 4. Open the pressure relief/drain valve (refer to “Opening the Truma pressure relief/drain valve” on page 11). The water container will drain via the drainage socket of the pressure relief/drain valve.
Winterizing Winter operation Severe damage to the plumbing To operate the Combi D furnace in potentially components and the Combi D furnace! freezing conditions, the following requirements Damage due to freezing or an unsuitable win- must be ensured: terizing fluid is not covered by warranty. •...
Truma Combi D comfort plus Technical Data Fuel Diesel (ULSD only) Fuel consumption 7.4 - 21.3 fl.oz./h (220 – 630 ml/h) 3.72 fl.oz./h (110 ml/h) at average Heat output of 3400 BTU/h (1 KW) Duct static pressure minimum of 0.00 in. wc (0.0 mbar) maximum of 0.65 in. wc (1.6 mbar)
/ or alterations of out- tute rental or for any other reason, even if Truma of-specification supplies, (ii) accidents, misuse, knew or should have known of the possibility of...
There are no serviceable parts inside. from the system. The residual heat in the device will heat the water to up to 158 °F In case of a defect please contact the Truma (70 °C). Service Center on 1-855-558-7862 or one of our authorized service partners to replace the complete furnace.
It must be replaced by a certified service technician. • A defective fuse must be replaced with the – It must only be replaced by the Truma pres- same make and model of fuse. sure relief/drain valve rated for 65.25 psi (4.5 bar) which is CSA certified and...
1 minute after the Limited combustion air Contact customer service. equipment is started. infeed. If none of the measures in the troubleshooting chart proves successful, please contact your dealer, the Truma Service Center on 1-855-558-7862 or one of our authorized service partners.
Page 20
In case you encounter any problems, please contact the Truma Service Center at 855-558-7862 or one of our authorized service partners. For details see www.truma.net. Please have the model number and serial number (on furnace’s type plate) handy when you call.