Maintenance, care and safety
Technical issues
Device
Batteries
– Dimensions: 9 cm diameter, approx.
– 2 x Micro AAA NiMH rechargeable
2.7 cm height
batteries included.
– Weight: approx. 130 g. w/ batteries
– Use of AAA 1.5 V batteries possible.
– Housing: impactresistant acrylic plastic
– Please follow disposal instructions!
– Temperature measurement range:
Battery charger - optional
34.5 to 41.0�C
– Accuracy: Device: 0.06�C; Sensor: 0.08�C
– Since battery chargers are countryspecific,
– Storage and transport conditions: –10 to
an interchangeable plug adapter for Europe
60�C, max. pressure 1500 hPa, 25 to 90%
and US is available.
humidity
Disposal
– Operating conditions: 5 to 40�C at
15 to 93% humidity
– Please use the public waste system for
– Use only up to 2000 m altitudes.
electrical devices.
Experience has shown that there are no
No risk of loss of data
reservations in use above 2000m.
Max. pressure 750 hPa. to 1500 hPa.
The data is preserved with depleted batteries.
Care – maintenance – safety
Cleaning – visible dirt
– Measuring sensor: to clean the sensor, use only
lukewarm water and avoid water penetration;
do not treat with aggressive cleaning agents.
– Housing: wipe with a slightly damp cloth
with glass cleaner.
– Please ensure that no water or other liquids
enter the device or the sensor as this may
cause failure or malfunction of the device.
– Do not use harsh chemicals, cleaning solvents,
or strong detergents to clean the Lady-Comp.
Care and maintenance
Your computer was developed and produced with
great care and therefore should also be treated
with care. By regarding the following notes you
will be able to appreciate your Lady-Comp for
a very long time.
– The computers have a minimum lifespan
of seven years.
– Protect your computer from moisture and
humidity to prevent damage to the device.
40
Do not place the device (even to dry) on /in
– If these instructions are lost, they can be
a heat source, such as in a microwave oven,
reordered at any time via our website
in an oven, or on a radiator.
or by phone.
– Do not leave the computer in hot areas. Do not
– The product is not intended for outdoor use.
place your computer for a long time in strong
– A damaged sensor and excessive dust can
sunlight or other UV light sources. High
impair its function.
temperatures can shorten the life of electronic
USB
devices, damage batteries, and warp or melt
plastic materials.
– To read the data, only devices that are able
– Do not store the device in cold areas. If it
to read a "Mass Storage Device" USB device
is then warmed again (back to its normal
are suitable. This applies to most standard
temperature), drops of moisture can form in
PCs, laptops, and many tablet computers.
the interior, which can damage the unit.
The USB connector may be used exclusively
– Do not drop the device and protect it from
for connection to such devices. While the
strong impacts or shocks to avoid equipment
Lady-Comp is connected via USB, no use
damage.
of the device is possible.
– If the sensor, the sensor cable or the housing
The notes above apply equally to the temperature
is damaged, the appliance should not be
sensor, the batteries, and the charger. If any of them
used further. A replacement sensor can
are not working properly, you can receive fast and
be ordered from the service center if it
reliable help from our distribution companies.
is defective, dirty, or damaged.
Safety
– Strong electromagnetic fields (i.e. mobile
phones, amateur radio, or microwaves) can
affect the device function. The minimum
safety distance is 1.5 m.
– The device must not be connected to devices
other than those specified. These must comply
with the standard IEC609501, as this could
otherwise lead to the damage of the device
or risks (e.g. electric shock).
– Keep the device away from small children
and pets.
– Make no modifications to the device.
– Use only within the specified operating
conditions and temperature range.
– During the red phase classic barrier methods
for contraception must be used, however
under no circumstances hormonal methods
like the pill.
– Lady-Comp is not suitable to measure the
body temperature within the meaning of
selfmonitoring of health status as a fever
thermometer is.
41
Need help?
Do you have a question about the Lady-Comp and is the answer not in the manual?