Eizo coloredge prominence CG3145 User Manual page 22

Hdr reference monitor
Hide thumbs Also See for coloredge prominence CG3145:
Table of Contents

Advertisement

Function
Luminance Warning
Co-View
Marker
Safe Area
Marker
Safe Area
Size
22
Chapter 3 Advanced Adjustments/Settings
Adjustable
Range
Off
You can check areas with a brightness that is higher than the
On (Yellow)
brightness that is set for the PQ Clipping function for the input
On (Magenta)
signal (areas where clipping occurs).
Note
• If this function is set to "On", the "REC709 Gamut Warning"
function is automatically set to "Off".
Off
If this function is set to "On", the monitor can be easily viewed at
On
a wider angle, such as when multiple people are looking at the
monitor at the same time.
Note
• A halo effect might occur when this function is set to "On". This
function should normally be set to "Off".
Off
A safe area is an area that can be displayed on any type of device.
On
If this function is set to "On", a frame is displayed around the safe
area during video editing, etc. This allows you to visually confirm
that subtitles and menus are arranged completely within the safe
area.
Note
• If
"Picture Setup" (page 32)
menu is set to "Dual", a frame is displayed around the safe area
only if the left and right screens have the same resolution.
• If "Aspect Marker" is set to any setting other than "Off", the safe
area setting is automatically set to "Off".
80 % to 99 %
You can set the size of the safe area.
Description
Example: Setting On (Magenta)
in the "Administrator Settings"

Advertisement

Table of Contents
loading

Table of Contents