Firstech CM-900 Installation Manual page 27

Remote start system
Hide thumbs Also See for CM-900:
Table of Contents

Advertisement

IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2.
Special Option Group 1
FO1- Diesel Timer: (Option 2-03 must first be set to setting 2.) This special option allows a
specific wait to start time (in seconds) to be programmed. This prevents the need for a timer relay
and eliminates a connection to the "wait to start" wire.
FO2 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option allows
a specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500 update,
latched output time 1-15 minutes are available for programming in addition to the standard
1-99 seconds.
FO3 - Aux 2 Output Timing: (Option 4-02 must first be set to setting 4.) This special option allows
a specific output duration for Aux 2 to be programmed 1-99 seconds. Note with OP500 update,
latched output time 1-15 minutes are available for programming in addition to the standard
1-99 seconds.
Special Option Group 2
This special option group allows you to determine the output type of the POC wire. For example, if you
want to set POC #5 (default setting status out) to Aux 1, you will need change special option 5 to number
10. This must be done with the OP500.
POC 1 – Green/White • Negative Parking Light Output: (default setting) This channel will
provide a 250mA (-) negative output when the CM-900 is armed (function also POC setting 1)
POC 2 – Blue/Green • Lock: (default setting) This channel will provide a 250mA output with the
lock/arm command. (function also POC setting 25)
POC 3 - Blue • Unlock: (default setting) This channel will provide a 250mA output with the
unlock/disarm command. (function also POC setting 26)
POC 4 - Black • GWR (ground when running aka status output): (default setting) This channel
will provide a 250mA output with the remote start activation command and continue to provide
output until 100mS after the remote start process has shut own. (function also POC setting 5)
POC 5 - Orange • FAA (Factory Alarm Ream): (default setting) This channel will provide a
250mA output with the lock/arm command. Note: the CM-900 will provide this output approx.
100mS before the unlock output. (function also POC setting 6)
POC 6 - Orange/White • FAD (Factory Alarm Disarm): (default setting) This channel will provide
a 250mA output with the unlock/disarm command. Note: the CM-900 will provide this output
approx. 100mS before the unlock output. (function also POC setting 7)
POC 7 - White • Horn: (default setting) This channel will provide a 250mA output when Horn is
triggered. (function also POC setting 8)
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents