Installation (for qualified installers only)
Horizontal Termination with Three 90° Elbows (all vertical)
If using a Snorkel Termination (14" (356mm) or 36" (915mm)) add the snorkel height to the vertical
height (snorkel terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
21' max (6.4m)
15 feet (4.5m)
10' min (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
This is a horizontal elbow -
NOT ALLOWED FOR THIS
VENT CONFIGURATION
10/2/17 - 1454
Restrictor
Position # 5
NOTE:
Restrictor positions are based
upon lab tests. The ideal restrictor
position may vary slightly,
especially when the termination is
near a demarkation line.
21' max (6.4m)
15 feet (4.5m)
10' min (3m)
5 feet (1.5m)
0 feet
These are
vertical elbows.