Specifications
Type
Max. SPL
(1 k
Ω
load)
Condenser Microphone
CMH8A: 132dB SPL
CMH8B: 142dB SPL
Element
CMH8C:
Pressure gradient,
Cardioid: 138dB SPL
FET preamplifier
Figure 8: 142dB SPL
Omni.: 142dB SPL
Polar pattern
(THD 0.5% 1kHz)
CMH8A/CMH8B:
Dynamic range
Cardioid (Figure 1)
at 1 k
CMH8C: Cardioid /
Figure 8
/
CMH8A: 114dB
Omnidirectional
(Figure 2)
CMH8B/CMH8C: 124dB
Frequency response
Power supply
30 to 20,000 Hz (Figure 3)
48 Vdc phantom power
Sensitivity
Current consumption
(at 1,000 Hz Open Circuit Voltage)
CMH8A/CMH8B: 2.7mA
CMH8A/CMH8B:
CMH8C: 4mA
-34dBV/Pa (20mV/Pa)
CMH8C:
Polarity
Cardioid: -31dBV/Pa (28mV/Pa)
Pin 2 output positive voltage
Figure 8: -35dBV/Pa (17mV/Pa)
(related to pin 3) when diaphragm
receives positive pressure.
Omni.: -35dBV/Pa (17mV/Pa)
(Diaphragm moving inward)
1Pa=94dB SPL
Connector
Rated impedance
3 pin male XLR type
200Ω
Finish
Minimum load impedance
Champagne finish
1000Ω
Dimensions
Equivalent noise level
Φ54.0mm(2.13in.) X 209.0mm
(A-weighted)
(8.23in.) (Figure 4)
CMH8A/CMH8B: 18dB
CMH8C:
Net weight
Cardioid: 14dB
CMH8A/CMH8B: 550g(19.40oz.)
Figure 8: 18dB
CMH8C: 565g(19.93oz.)
Omni.: 18dB
CMH8A/H8B
TYPICAL POLAR PATTERN
Ω
Load
CMH8C
CARDIOID TYPICAL POLAR PATTERN
CMH8C
Omni
TYPICAL POLAR PATTERN
TYPICAL POLAR PATTERN
(Figure 2)
dB
10
0
-10
-20
20
50
100
200
500
1000
2000
FREQUENCY IN Hz
dB
10
0
-10
-20
20
50
100
200
500
1000
2000
FREQUENCY IN Hz
dB
10
0
-10
-20
20
50
100
200
500
1000
2000
FREQUENCY IN Hz
TYPICAL FREQUENCY RESPONSE (Figure 3)
(F
igure 1
)
Description
CMH8A/CMH8B are condenser cardioid microphones with large
diaphragm of 1" in diameter; while CMH8C features convertible polar
patterns of cardioid, figure-of-8 and omni. Their tailored frequency
response make them ideal candidate for the recording of music program.
They are also suitable for general recording, broadcasting, stage
reinforcement, etc.
CMH8C
Figure 8
Features
·
Large-diaphragm capsule of gold-evaporated membrane 1" in
μ
CM-H8A
diameter and 3 m in thickness.
·
Low-noise transformer circuit.
·
Wide frequency response.
·
CMH8A has built-in low-cut filter.
·
5000
10000
20000 Hz
CMH8B
has an extezrnal switch for low-cut filter and -10dB roll-off.
CM-H8B
·
CMH8C
has a dual-membrane capsule with external switches for low-
cut filter and -10dB roll-off. At the back of the body, there is a switch
for converting polar patterns among cardioid, figure-of-8 and omni.
5000
10000
20000 Hz
CM-H8C
Converting
polar patterns
H8C
5000
10000
20000 Hz
(Figure 4)
Low Frequency
Off-Roll
-10dB PAD
H8B H8C
H8B H8C

Advertisement

loading
Need help?

Need help?

Do you have a question about the CMH8C and is the answer not in the manual?

Questions and answers

Summary of Contents for Superlux CMH8C

  • Page 1: User Guide

    CMH8A/CMH8B are condenser cardioid microphones with large Sensitivity Current consumption (at 1,000 Hz Open Circuit Voltage) diaphragm of 1" in diameter; while CMH8C features convertible polar CMH8A/CMH8B: 2.7mA CMH8A/CMH8B: patterns of cardioid, figure-of-8 and omni. Their tailored frequency CMH8C: 4mA -34dBV/Pa (20mV/Pa) response make them ideal candidate for the recording of music program.
  • Page 2 Carrying case adaptor connector Double diaphragm structure with cardioid acoustic nature, CMH8C can be set at OMNI, Condenser microphones work with power. Professional standard is 48VDC phantom Cardioid, and Figure-8 polar mode. power. Some microphones work with lower voltage as low as 1.5VDC, such as battery Optional accessories power model.

This manual is also suitable for:

Cmh8bCmh8a