FEATURES
CONTROL PANEL FEATURES iGen4500
120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R):
1
The outlet is capable of carrying a maximum of 20
amps.
120-Volt 30 Amp TT-30 Outlet: Travel Trailer
2
outlet can supply a maximum of 30 amps and
120 volts.
20-Amp Circuit Breakers: Each circuit breaker
3
limits the current that can be delivered through
the 120-volt duplex outlets to 20amps.
4
30-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through
the 120-volt TT-30 outlets to 30amps.
5
USB Duplex: 5V DC USB outlets that come with 1
and 2.1 amp rating.
Reset Breaker: If the inverter is overloaded, the
6
reset breaker will trip. The engine will continue to
run, but there will be no output from the inverter.
Unplug the devices and reduce the load. Push in
the reset breaker to reset it.
7
Efficiency Mode Switch: When turned to the ON
position, the engine will sense the load needed
and run at a slower RPM to save fuel.
Ground Terminal: The ground terminal is used to
8
externally ground the inverter.
LED Data Center: Displays remaining run time (F),
9
power output in kW (P), fuel level in liters (L) and
voltage (V).
% FUEL
REMAINING
AUTOMATIC ROTATING DATA NUMBER DISPLAY
Remaining Run Time:
Displays time remaining
with current fuel level and
power output. Does not
display lifetime hours.
8 | Westinghouse Portable Power
% POWER
OUTPUT
Power Output:
Displays electrical power
output to receptacles in
kilowatts.
1
3
4
8
Output Ready LED: Indicates the inverter is
10
ready to be used.
11
Overload LED: Indicates that the inverter is
overloaded.
12
Low Oil LED: Indicates low oil level.
Battery Charging Port: Used to charge battery
13
when unit is off.
Fuel Control Switch: Allows fuel to flow to the
14
engine.
Start Indicator: Indicates that power is on, light
15
will remain lit the whole time the unit is on.
Push Button Automated Start: Push once to
16
automatically start the engine. Push again to
stop the engine.
17
Battery Switch: Turns battery on and off. Must be
on before electric start.
18
Main Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator.
Fuel level:
Displays current fuel
level in liters.
5
15
7
2
10 11 12
18
17
16
6
Voltage:
Displays current voltage
output of generator.
14
13
9

Hide quick links: