IBM StorageSmart DF1100R Operator's Manual page 16

Profibre storage array raid controller unit storage expansion unit
Table of Contents

Advertisement

Figure 5. Fan-and-Power-Supply Assembly Lights and Switch
A fan-and-power-supply assembly has the following lights and switch:
AC PWR light 1
DC PWR light 2
CHK light 3
DC On/Standby switch 4
6
ProFibre Storage Array: Operator's Guide
The AC PWR light, which is green, comes on when the mainline power
supply is connected to the fan-and-power-supply assembly.
The DC PWR light, which is green, comes on when this
fan-and-power-supply assembly is supplying power to the ProFibre
Storage Array unit.
The CHK light, which is amber, indicates a failure in the
fan-and-power-supply assembly.
Note: This light is always off when the DC On/Standby switch is set to
standby.
The DC On/Standby switch connects dc electrical power from the
fan-and-power-supply assembly to the disk drives and other components
in the ProFibre Storage Array unit. This switch must be set to on for the
fan-and-power-supply unit to start.
If the DC On/Standby switch on either of the two fan-and-power-supply
assemblies is set to on, power in the ProFibre Storage Array unit is
switched on automatically if all of the following conditions exist:
v Input power to the ProFibre Storage Array is present.
v The fan-and-power-supply assembly is fully inserted into its slot.

Advertisement