Fan-And-Power-Supply Assemblies - IBM StorageSmart DF1100R Operator's Manual

Profibre storage array raid controller unit storage expansion unit
Table of Contents

Advertisement

Off
On
Flashing
2 Check light
The Check light, which is amber, shows the following conditions:
Off
Permanently On
Flashing (0.5 seconds on, 0.5 seconds off)

Fan-and-Power-Supply Assemblies

Two fan-and-power-supply assemblies 1 are installed in the back of a unit in the
ProFibre Storage Array.
The power switch and lights are visible at the back of the unit.
Figure 4. Fan-and-Power-Supply Assemblies
Note: The diagram shows controller units. The fan-and-power-supply assemblies
are in the same position in expansion units.
The disk drive module is not powered on.
The disk drive module is ready but not active.
This disk drive module is active with a command in progress.
Normal operating condition.
The drive has reported a Predictive Failure Analysis
(this error indicates that the disk drive has had an excessive
number of internally recovered errors),
OR the disk drive is faulty (this is an SES function).
The data on this disk drive is being rebuilt using data on other
disk drives in the same array. Flashing of the light is controlled by
a SES function.
®
(PFA) error