Hitachi WJ200-001SF Manual page 11

Wj200 series
Hide thumbs Also See for WJ200-001SF:
Table of Contents

Advertisement

Code
Function Name
A019
Multi-speed operation selection
A020
Multi-speed 0 setting
A220
Multi-speed 0 setting, 2nd motor
A021
l
Multi-speed 1 – 15 setting
A035
A038
Jog frequency setting
A039
Jog stop mode
A041
Torque boost select
A241
Torque boost select, 2nd motor
A042
Manual torque boost value
A242
Manual torque boost value, 2nd motor
A043
Manual torque boost frequency adjustment
A243
Manual torque boost frequency adjustment, 2nd motor
A044
V / f characteristic curve selection
A244
V / f characteristic curve selection, 2nd motor
A045
V / f gain setting
A245
V / f gain setting, 2nd motor
A046
Voltage compensation gain for automatic torque boost
Voltage compensation gain for automatic torque boost,
A246
2nd motor
A047
Slip compensation gain for automatic torque boost
S lip c o m p e n s a t i o n g ai n f o r a u t o m a t i c t o r q u e b o o s t ,
A247
2nd motor
A051
DC braking enable
A052
DC braking frequency setting
A053
DC braking wait time
A054
DC braking force for deceleration
A055
DC braking time for deceleration
A056
DC braking / edge or level detection for [DB] input
A057
DC braking force at start
A058
DC braking time at start
A059
Carrier frequency during DC braking
A061
Frequency upper limit setting
A261
Frequency upper limit setting, 2nd motor
A062
Frequency lower limit setting
A262
Frequency lower limit setting, 2nd motor
A063
Jump (center) frequency setting 1
A064
Jump (hysteresis) frequency width setting 1
A065
Jump (center) frequency setting 2
A066
Jump (hysteresis) frequency width setting 2
A067
Jump (center) frequency setting 3
A068
Jump (hysteresis) frequency width setting 3
A069
Acceleration stop frequency setting
A070
Acceleration stop time setting
A071
PID enable
A072
PID proportional gain
A073
PID integral time constant
A074
PID derivative time constant
A075
PV scale conversion
A076
PV source setting
A077
Reverse PID action
A078
PID output limit
A079
PID feed forward selection
A081
AVR function select
A281
AVR function select, 2nd motor
A082
AVR voltage select
A282
AVR voltage select, 2nd motor
A083
AVR filter time constant
A084
AVR deceleration gain
Stöwer Antriebstechnik GmbH, Enneststrasse 3, 51702 Bergneustadt, tel: 02261-40970, Fax: 02261-41309
Setting Range
00 (Binary mode) / 01 (Bit mode)
0.00 / "start frequency" to "maximum frequency (1st)" [Hz]
0.00 / "start frequency" to "maximum frequency (2nd)" [Hz]
0.00 / "start frequency" to "maximum frequency" [Hz]
"start frequency" to 9.99 [Hz]
00 (Free-run stop [invalid during run]) /
01 (Controlled deceleration [invalid during run]) /
02 (DC braking to stop [invalid during run]) /
03 (Free-run stop [valid during run])
04 (Controlled deceleration [valid during run])
05 (DC braking to stop [valid during run])
00 (manual torque boost) /
01 (automatic torque boost)
0.0 to 20.0 [%]
0.0 to 20.0 [%]
0.0 to 50.0 [%]
0.0 to 50.0 [%]
00 (VC) / 01 (VP) / 02 (free V / f) / 03 (SLV)
00 (VC) / 01 (VP) / 02 (free V / f) / 03 (SLV)
20 to 100 [%]
20 to 100 [%]
0 to 255
0 to 255
0 to 255
0 to 255
00 (disabled) / 01 (enabled) / 02 (output freq < [A052])
0.00 to 60.00 [Hz]
0.0 to 5.0 [s]
0 to 100 / 70 [%] (CT / VT)
0.0 to 60.0 [s]
00 (edge operation) / 01 (level operation)
0 to 100 / 70 [%] (CT / VT)
0.0 to 60.0 [s]
2.0 to 15.0 / 10.0 [kHz] (CT / VT)
0.00 / A062 to A004 [Hz]
0.00 / A262 to A204 [Hz]
0.00 / b082 to A061 [Hz]
0.00 / b082 to A261 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 10.00 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 10.00 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 10.00 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.0 to 60.0 [s]
00 (disabled) / 01 (enabled) / 02 (enabled inverted-data output)
0.00 to 25.00
0.0 to 999.9 / 1000. to 3600. [s]
0.00 to 99.99 / 100.0 [s]
0.01 to 99.99
00 (input via OI) / 01 (input via O) / 02 (external communication) /
03 (pulse train frequency input) / 10 (operation result output)
00 (OFF) / 01 (ON)
0.0 to 100.0 [%]
00 (disabled) / 01 (O input) / 02 (OI input)
00 (always on) / 01 (always off) / 02 (off during deceleration)
00 (always on) / 01 (always off) / 02 (off during deceleration)
200 V class : 200 / 215 / 220 / 230 / 240 (V)
400 V class : 380 / 400 / 415 / 440 / 460 / 480 (V)
200 V class : 200 / 215 / 220 / 230 / 240 (V)
400 V class : 380 / 400 / 415 / 440 / 460 / 480 (V)
0.000 to 9.999 / 10.00 [s]
50 to 200 [%]
[ ○ = Allowed × = Not parmitted]
Setting During
Change During
Default
Operation
Operation
Setting
(allowed or not)
(allowed or not)
×
×
00
0.00
0.00
0.00
6.00
×
04
×
×
00
×
×
00
1.0
1.0
5.0
5.0
×
×
00
×
×
00
100
100
100
100
100
100
×
00
×
0.50
×
0.0
×
50
×
0.5
×
01
×
0
×
0.0
×
5.0
×
0.00
×
0.00
×
0.00
×
0.00
×
0.00
×
0.50
×
0.00
×
0.50
×
0.00
×
0.50
×
0.00
×
0.0
×
00
1.00
1.0
0.00
×
1.00
×
00
×
00
×
0.0
×
00
×
×
02
×
×
02
×
×
200 / 400
×
×
200 / 400
×
0.300
×
100
 13