3. MAINTENANCE MODE

Power ON indicator
Lights up when the stapler
folder is turned ON.

3-1. Entering the Maintenance Mode

Press the escape button once on the initial screen of the control panel. Turn the jog dial by three clicks towards the
right, "Number of Sheets" will be displayed. Press the clear button here once. A beep will be sounded.
Turn the jog dial by 5 clicks towards the left, "Fine Adjustment" will be displayed. Press the clear button here once. A
beep will be sounded.
After "Maintenance Menu" is displayed, press the jog dial once. Two beeps will be sounded.
The maintenance menu has four modes for selection – ROM version display, simulation mode, sensor check mode,
and motor/solenoid test mode.

3-2. ROM Version Display

Select ROM version display from the maintenance menu. The control program version of the MC unit, stepping motor
driver (SPM), or OP unit will be displayed.

3-3. Simulation Mode

When the simulation mode is selected from the maintenance menu, "Simulation Mode" will be displayed. Before
starting the simulation mode, be sure to remove the staple cartridge from the stapler.
Press the start button to start the machine in the simulation mode, and stop with the stop button.
In the simulation mode, each mechanism operates without paper.
Display
Clear
Escape
button
button
Jog dial/Enter button
Function
button
11C-M12M0-0004-0
Stop button
Start button