Standard Functions - Hitachi SJ700 series Manual

Powerful inverter with sensorless vector control
Hide thumbs Also See for SJ700 series:
Table of Contents

Advertisement

● A GROUP: STANDARD FUNCTIONS
Code
Function Name
A001
Frequency source setting
A002
Run command source setting
A003
Base frequency setting
A203
Base frequency setting, 2nd motor
A303
Base frequency setting, 3rd motor
A004
Maximum frequency setting
A204
Maximum frequency setting, 2nd motor
A304
Maximum frequency setting, 3rd motor
A005
[AT] selection
A006
[O2] selection
A011
O-L input active range start frequency
A012
O-L input active range end frequency
A013
O-L input active range start voltabe
A014
O-L input active range end voltabe
A015
O-L input active range start frequency selection
A016
External frequency Þ lter time constant
A017
Easy sequence function selection
A019
Multispeed operation selection
A020
Multispeed frequency setting
A220
Multispeed frequency setting, 2nd motor
A320
Multispeed frequency setting, 3rd motor
A021
Multispeed 1-15 setting
A035
A038
Jog frequency setting
A039
Jog stop mode
A041
Torque boost method selection
A241
Torque boost method selection, 2nd motor
A042
Manual torque boost value
A242
Manual torque boost value, 2nd motor
A342
Manual torque boost value, 3rd motor
A043
Manual torque boost frequency adjustment
A243
Manual torque boost frequency adjustment, 2nd motor
A343
Manual torque boost frequency adjustment, 3rd motor
V/F characteristic curve selection,
A044
1st motor (*5)
V/F characteristic curve selection,
A244
2nd motor (*5)
A344
V/F characteristic curve selection, 3rd motor
A045
V/f gain setting
Voltage compensation gain setting
A046
for automatic torque boost. 1st motor
Voltage compensation gain setting
A246
for automatic torque boost, 2nd motor
Slippage compensation gain setting
A047
for automatic torque boost, 1st motor
Slippage compensation gain setting
A247
for automatic torque boost, 2nd motor
A051
DC braking enable
A052
DC braking frequency setting
A053
DC braking wait time
A054
DC braking force during deceleration
A055
DC braking time for deceleration
A056
DC braking/edge or level detection for [DB] input
A057
DC braking force for starting
A058
DC braking time for starting
A059
DC braking carrier frequency setting
(*1) This setting is valid only when the OPE-SR is connected. (*2) 4000HF:30. to 120. (Hz)
(*3) Derating is applied for SJ700B. Please consult technician at Hitachi or its distributor before use. (*4) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz)
15
(*5) SJ700D (VTmode):00 (VC), 01 (VP), 02 (free V/F), 03 (sensorless vector control)
Monitored data or setting
00 (keypad potentiometer) (*1), 01 (control circuit terminal block),
02 (digital operator), 03 (RS485), 04 (option 1), 05 (option 2),
06 (pulse-string input), 07 (easy sequence), 10 (operation function result)
01 (control circuit terminal block), 02 (digital operator), 03 (RS485), 04 (option 1), 05 (option 2)
30. to "maximum frequency " (Hz)
30. to "maximum frequency, 2nd motor" (Hz)
30. to "maximum frequency, 3rd motor" (Hz)
"base frequency" to 400. (Hz) (*2)
"base frequency, 2nd motor" to 400. (Hz) (*2)
"base frequency, 3rd motor" to 400. (Hz) (*2)
00 (switching between O and OI terminals), 01 (switching between O and O2
terminals), 02 (switching between O terminal and keypad potentiometer) (*1), 03
(switching between OI terminal and keypad potentiometer) (*1), 04 (switching
between O2 and keypad potentiometer) (*1)
00 (single), 01 (auxiliary frequency input via O and OI terminals) (nonreversible),
02 (auxiliary frequency input via O and OI terminals) (reversible), 03 (disabling
O2 terminal)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*4)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*4)
0. to "[O]-[L] input active range end voltage" (%)
"[O]-[L] input active range start voltage" to 100. (%)
00 (external start frequency), 01 (0 Hz)
1. to 30. or 31. (500 ms Þ lter ±0.1 Hz with hysteresis)
00 (disabling), 01 (enabling)
SJ700D: 00 (disabling), 01 (PRG terminal), 02 (always on)
00 (binary: 16 speeds selectable with 4 terminals), 01 (bit: 8 speeds selectable with 7 terminals)
0.00 or "start frequency" to "maximum frequency" (Hz)
0.00 or "start frequency" to "maximum frequency, 2nd motor" (Hz)
0.00 or "start frequency" to "maximum frequency, 3rd motor" (Hz)
0.00 or "start frequency" to "n-th maximum frequency" (Hz)
"Start frequency" to 9.99 (Hz)
00 (free-running after jogging stops [disabled during operation]), 01 (deceleration
and stop after jogging stops [disabled during operation]), 02 (DC braking after
jogging stops [disabled during operation]), 03 (free-running after jogging stops
[enabled during operation]), 04 (deceleration and stop after jogging stops [enabled
during operation]), 05 (DC braking after jogging stops [enabled during operation])
00 (Manual torque boost) / 01 (Automatic torque boost)
00 (Manual torque boost) / 01 (Automatic torque boost)
0.0 to 20.0 (%)
0.0 to 20.0 (%)
0.0 to 20.0 (%)
0.0 to 50.0 (%)
0.0 to 50.0 (%)
0.0 to 50.0 (%)
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control),
04 (0Hz-range sensorless vector), 05 (vector with sensor)
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control),
04 (0Hz-range sensorless vector)
00 (VC), 01 (VP)
20. to 100. (%)
0. to 255.
0. to 255.
0. to 255.
0. to 255.
00 (disabling), 01 (enabling), 02 (set frequency only)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*4)
0.0 to 5.0 (s)
SJ700/SJ700D (CT): 0. to 100. (%) <75 to 132kW:0. to 80./185kW and over:0. to 35.>
SJ700D (VT): 0. to 70. (%) <75 to 132kW:0. to 50.>
SJ700B: 0. to 70. (%) <90kW and over:0. to 50.>
0.0 to 60.0 (s)
00 (edge operation), 01 (level operation)
SJ700/SJ700D (CT): 0. to 100. (%) <75 to 132kW:0. to 80./185kW and over:0. to 35.>
SJ700D (VT): 0. to 70. (%) <75 to 132kW:0. to 50.>
SJ700B: 0. to 70. (%) <90kW and over:0. to 50.>
0.0 to 60.0 (s)
SJ700/SJ700D (CT): 0.5 to 15.0(kHz) <75 to 132kW:0.5 to 10.0/185kW and over:0.5 to 3.0>
SJ700D (VT): 0.5 to 12.0 (kHz) <75 to 132kW:0.5 to 8.0>
SJ700B: 0.5 to 12.0 (kHz) <90kW and over:0.5 to 8.0>
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
01
01
02
01
02
01
01
02
01
02
50.
60.
60.
50.
60.
50.
60.
60.
50.
60.
50.
60.
60.
50.
60.
50.
60.
60.
50.
60.
50.
60.
60.
50.
60.
50.
60.
60.
50.
60.
00
00
00
00
00
03
03
03
03
03
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.
0.
0.
0.
0.
100.
100.
100.
100.
100.
01
01
01
01
01
31.
31.
31.
31.
31.
00
00
00
00
00
00
00
00
00
00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1.00
1.00
1.00
1.00
1.00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
00
00
00
00
00
0.50
0.50
0.50
0.50
0.50
0.0
0.0
0.0
0.0
0.0
0
0
0
0
20.0
0.0
0.0
0.0
0.0
0.5
01
01
01
01
01
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
5.0
3.0
3.0
<75 to 132kW:3.0>
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj700b series

Table of Contents