Code
Function Name
C021
Terminal (11) function
C022
Terminal (12) function
C023
Terminal (13) function
C024
Terminal (14) function
C025
Terminal (15) function
C026
Alarm relay terminal function
C027
FM signal selection
C028
AM signal selection
C029
AMI signal selection
C030
Digital current monitor reference value
C031
Terminal (11) active state
C032
Terminal (12) active state
C033
Terminal (13) active state
C034
Terminal (14) active state
C035
Terminal (15) active state
C036
Alarm relay terminal active state
Low-current indication signal output mode
C038
selection
C039
Low-current indication signal detection level
C040
Overload signal output mode
C041
Overload level setting
C042
Frequency arrival setting for accel.
C043
Frequency arrival setting for decel.
C044
PID deviation level setting
C045
Frequency arrival setting for acceleration (2)
C046
Frequency arrival setting for deceleration (2)
C052
Maximum PID feedback data
C053
Minimum PID feedback data
C055
Over-torque (Forward-driving) level setting
Over-torque (Reverse-regenerating)
C056
level setting
C057
Over-torque (Reverse-driving) level setting
Over-torque (Forward-regenerating)
C058
level setting
C061
Electronic thermal warning level setting
C062
Alarm code input
C063
Zero speed detection level
C064
Heat sink overheat warning level
C071
Communication speed selection (*2)
C072
Node allocation
C073
Communication data length selection
C074
Communication parity selection
C075
Communication stop bit selection
(*1) 4000HF:0.00 to 99.99, 100.0 to 120.0 (Hz)
Monitored data or setting
00 (RUN: running), 01 (FA1: constant-speed reached), 02 (FA2: set frequency
overreached), 03 (OL: overload notice advance signal (1)), 04 (OD: output
deviation for PID control), 05 (AL: alarm signal), 06 (FA3: set frequency
reached), 07 (OTQ: over-torque), 08 (IP: instantaneous power failure), 09 (UV:
undervoltage), 10 (TRQ: torque limited), 11 (RNT: operation time over), 12 (ONT:
plug-in time over), 13 (THM: thermal alarm signal), 19 (BRK: brake release), 20
(BER: braking error), 21 (ZS: 0 Hz detection signal), 22 (DSE: speed deviation
maximum), 23 (POK: positioning completed),24 (FA4: set frequency overreached
2), 25 (FA5: set frequency reached 2), 26 (OL2: overload notice advance
signal (2)), 27 (Odc: Analog O disconnection detection), 28 (OIDc: Analog OI
disconnection detection), 29 (O2Dc: Analog O2 disconnection detection), 31
(FBV: PID feedback comparison), 32 (NDc: communication line disconnection),
33 (LOG1: logical operation result 1), 34 (LOG2: logical operation result 2),
35 (LOG3: logical operation result 3), 36 (LOG4: logical operation result 4), 37
(LOG5: logical operation result 5), 38 (LOG6: logical operation result 6), 39 (WAC:
capacitor life warning) (*2), 40 (WAF: cooling-fan speed drop), 41 (FR: starting
contact signal), 42 (OHF: heat sink overheat warning), 43 (LOC: low-current
indication signal), 44 (M01: general-purpose output 1), 45 (M02: general-purpose
output 2), 46 (M03: general-purpose output 3), 47 (M04: general-purpose output
4), 48 (M05: general-purpose output 5), 49 (M06: general-purpose output 6),
50 (IRDY: inverter ready), 51 (FWR: forward rotation), 52 (RVR: reverse rotation),
53 (MJA: major failure), 54 (WCO: window comparator O), 55 (WCOI: window
comparator OI), 56 (WCO2: window comparator O2) (When alarm code output
is selected for "C062", functions "AC0" to "AC2" or "AC0" to "AC3" [ACn: alarm
code output] are forcibly assigned to intelligent output terminals 11 to 13 or 11
to 14, respectively.)
00 (output frequency), 01 (output current), 02 (output torque), 03 (digital
output frequency), 04 (output voltage), 05 (input power), 06 (electronic thermal
overload), 07 (LAD frequency), 08 (digital current monitoring), 09 (motor
temperature), 10 (heat sink temperature), 12 (general-purpose output YA0)
00 (output frequency), 01 (output current), 02 (output torque), 04 (output
voltage), 05 (input power), 06 (electronic thermal overload), 07 (LAD frequency),
09 (motor temperature), 10 (heat sink temperature), 11 (output torque [signed
value]), 13 (general-purpose output YA1)
00 (output frequency), 01 (output current), 02 (output torque), 04 (output voltage),
05 (input power), 06 (electronic thermal overload), 07 (LAD frequency), 09 (motor
temperature), 10 (heat sink temperature), 14 (general-purpose output YA2)
SJ700/SJ700D:0.20 x "rated current" to 2.00 x "rated current" (A) / SJ700B:0.20
x "rated current" to 1.50 x "rated current" (A)
(Current with digital current monitor output at 1,440 Hz)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
SJ700/SJ700D (CT):0.0 to 2.00 x "rated current" (A)
< 75kW and over:0.0 to 1.80 x "rated current" (A)>
SJ700D (VT)/SJ700B:0.0 to 1.50 x "rated current" (A)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
SJ700/SJ700D (CT):0.0 to 2.00 x "rated current" (A)
< 75kW and over:0.0 to 1.80 x "rated current" (A)>
SJ700D (VT)/SJ700B:0.0 to 1.50 x "rated current" (A)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.0 to 100.0 (%)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
SJ700/SJ700D (CT): 0. to 200. (%) < 75kW and over:0. to 180.>
SJ700D (VT)/SJ700B: 0. to 150. (%)
SJ700/SJ700D (CT): 0. to 200. (%) < 75kW and over:0. to 180.>
SJ700D (VT)/SJ700B: 0. to 150. (%)
SJ700/SJ700D (CT): 0. to 200. (%) < 75kW and over:0. to 180.>
SJ700D (VT)/SJ700B: 0. to 150. (%)
SJ700/SJ700D (CT): 0. to 200. (%) < 75kW and over:0. to 180.>
SJ700D (VT)/SJ700B: 0. to 150. (%)
0. to 100. (%)
00 (Disabled) / 01 (3-bit) / 02 (4-bit)
0.00 to 99.99, 100.0 (Hz)
0. to 200.0 (
)
SJ700D: 02 (loopback test), 03 (2,400 bps), 04 (4,800 bps), 05 (9,600 bps),
06 (19,200 bps), 07 (38,400 bps), 08 (57,600 bps), 09 (76,800 bps), 10 (115,200 bps)
SJ700/SJ700B: 02 (loopback test), 03 (2,400 bps), 04 (4,800 bps), 05 (9,600 bps),
06 (19,200 bps)
SJ700D: 1 to 247, SJ700/SJ700B: 1 to 32
7 (7 bits), 8 (8 bits)
00 (no parity), 01 (even parity), 02 (odd parity)
1 (1 bit), 2 (2 bits)
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
01
01
01
01
01
(FA1)
(FA1)
(FA1)
(FA1)
(FA1)
00
00
00
00
00
(RUN)
(RUN)
(RUN)
(RUN)
(RUN)
03
03
03
03
03
(OL)
(OL)
(OL)
(OL)
(OL)
07
07
07
07
07
(OTO)
(OTO)
(OTO)
(OTO)
(OTO)
40
40
40
40
40
(WAF)
(WAF)
(WAF)
(WAF)
(WAF)
05
05
05
05
05
(AL)
(AL)
(AL)
(AL)
(AL)
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Rated current of
inverter x 1.00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
01
01
01
01
01
01
01
01
01
01
Rated current of inverter x 1.00
01
01
01
01
01
Rated current of inverter x 1.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
3.0
3.0
3.0
3.0
3.0
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
100.0 100.0 100.0 100.0 100.0
0.0
0.0
0.0
0.0
0.0
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
80.
80.
80.
80.
80.
00
00
00
00
00
0.00
0.00
0.00
0.00
0.00
120.
120.
120.
120.
120.
04
04
04
04
04
1.
1.
1.
1.
1.
7
7
7
7
7
00
00
00
00
00
1
1
1
1
1
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj700b series

Table of Contents