Code
Function Name
Selection of the operation after
C076
communication error
C077
Communication timeout limit before tripping
C078
Communication wait time
C079
Communication mode selection
C081
O input span calibration
C082
OI input span calibration
C083
O2 input span calibration
C085
Thermistor input tuning
C091
Debug mode enable
C101
UP/DOWN memory mode selection
C102
Reset mode selection
C103
Restart mode after reset
C105
FM gain adjustment
C106
AM gain adjustment
C107
AMI gain adjustment
C109
AM bias adjustment
C110
AMI bias adjustment
C111
Overload setting (2)
C121
O input zero calibration
C122
OI input zero calibration
C123
O2 input zero calibration
C130
Output 11 on-delay time
C131
Output 11 o -delay time
C132
Output 12 on-delay time
C133
Output 12 o -delay time
C134
Output 13 on-delay time
C135
Output 13 o -delay time
C136
Output 14 on-delay time
C137
Output 14 o -delay time
C138
Output 15 on-delay time
C139
Output 15 o -delay time
C140
Output RY on-delay time
C141
Output RY o -delay time
C142
Logical output signal 1 selection 1
C143
Logical output signal 1 selection 2
C144
Logical output signal 1 operator selection
C145
Logical output signal 2 selection 1
C146
Logical output signal 2 selection 2
C147
Logical output signal 2 operator selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
C168
Input terminal response time setting FW
C169
Multistage speed/position determination time
21
Monitored data or setting
00 (tripping), 01 (tripping after decelerating and stopping the motor), 02 (ignoring
errors), 03 (stopping the motor after free-running), 04 (decelerating and stopping
the motor)
0.00 to 99.99 (s)
0. to 1000. (ms)
00 (ASCII), 01 (Modbus-RTU)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 ∼ 65530)
0. to 9999., 1000 to 6553 (10000 ∼ 65530)
0.0 to 999.9, 1000.
(Do not change this parameter, which is intended for factory adjustment.)
00 (not storing the frequency data), 01 (storing the frequency data)
00 (resetting the trip when RS is on), 01 (resetting the trip when RS is o ),
02 (enabling resetting only upon tripping [resetting when RS is on]),
03 (resetting only trip)
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (restarting with active matching frequency)
50. to 200. (%)
50. to 200. (%)
50. to 200. (%)
0. to 100. (%)
0. to 100. (%)
SJ700/SJ700D (CT):0.0 to 2.00 x "rated current" (A)
<75kW and over:0.0 to 1.80 x "rated current">
SJ700D (VT)/SJ700B:0.0 to 1.50 x "rated current" (A)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×10ms)
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
02
02
02
02
02
0.00
0.00
0.00
0.00
0.00
0.
0.
0.
0.
0.
00
00
00
00
00
Factory set
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
0.
0.
0.
0.
0.
20.
20.
20.
20.
20.
Rated current of
inverter x 1.00
Factory set
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links: