Outland Living FMPPC2E-410 Owner's Manual
Hide thumbs Also See for FMPPC2E-410:

Advertisement

Model number FMPPC2E-410
FMI BRANDS INC.
107 – 19052 26 Avenue | Surrey, B.C. Canada V3Z 3V7 | Toll Free 1-888-514-1663 | Fax 1-888-797-9931
Owner's
Manual
Wicker colour may be
different than shown.
D.410.000.V0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMPPC2E-410 and is the answer not in the manual?

Questions and answers

Summary of Contents for Outland Living FMPPC2E-410

  • Page 1 Owner’s Manual Wicker colour may be different than shown. Model number FMPPC2E-410 D.410.000.V0 FMI BRANDS INC. 107 – 19052 26 Avenue | Surrey, B.C. Canada V3Z 3V7 | Toll Free 1-888-514-1663 | Fax 1-888-797-9931...
  • Page 2: Carbon Monoxide Hazard

    Owner & Safety Manual Model number FMPPC2E-410 - Tested by CSA International DANGER: If you smell gas: 1. Shut off gas to the appliance. WARNING! HOT SURFACE! 2. Extinguish any open flame. 3. If odour continues, keep away from the appliance and immediately call your gas supplier or fire department.
  • Page 3: Minimum Clearances

    Disconnected cylinders must have threaded valve plugs tightly WARNING: installed and must not be stored in a building, garage or any other enclosed area. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the The gas pressure regulator provided with this appliance must installation, operating and maintenance instructions thoroughly be used, and must be the same model as supplied with the unit.
  • Page 4: Leak Test

    Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 in (3.2 mm) diameter rod. Ventilation openings in sidewalls shall not communicate directly with other enclosures of the appliance. En-3 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 5 THE APPLIANCE IS NOT TO BE USED UNTIL ANY LEAK IS CORRECTED. A gas appliance repairman or LP gas dealer should be called if attempts to stop the leak(s) are unsuccessful and, in such case, the LP gas supply must be shut off at the cylinder valve or the cylinder must be removed from the appliance until the leak(s) is corrected.
  • Page 6 End Panel with Gas Valve, Gas Hose and Regulator Mounting Bracket Assembly End Panel Cross Bar Propane Cylinder H-Frame Support Side Panel M6 screw (+ 1 extra) (1 Bag) Glass Fire Rocks En-5 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 7 SECTION 1: ASSEMBLY STEP 2A WARNING: Fix the End panel with gas valve, gas hose and regulator mounting bracket assembly to the table top with 4 screws. DO NOT CUT STRAPS WITH TABLE TOP STANDING UP. IMPORTANT: Align gas valve orifice inside burner tube. NOTE: to simplify the assembly drawings the gas hose with regulator is not shown.
  • Page 8 END PANEL PRESS FIT STUDS STEP 5B Press-fit the cylinder H-frame support on studs. STEP 4 Mount (2x) Cross Bars. (2x) CROSS BARS (8x) M6 SCREWS PROPANE CYLINDER H-FRAME SUPPORT En-7 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 9 SECTION 1: ASSEMBLY (continued) STEP 6 CAUTION! Watch for metal crimps. Avoid damaging the Cut and remove straps. wicker when removing straps. SCISSORS KNIFE METAL CAUTION! Watch for metal crimps located UNDER TABLE CRIMP when removing straps. METAL CRIMP METAL CRIMP STEP 7: PROPANE CYLINDER ASSEMBLY Place an approved 20lb propane cylinder in to cylinder ring (Part 6).
  • Page 10 Avoid glass dust. Always wear gloves to handle rocks; caution for glass dust when handling; use a rag to wipe glass dust. Glass dust may result during shipping. NOTE: Rocks are not to exceed 7kg or 15.5lbs. En-9 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 11 NOTE TO USER: Before igniting the unit for the first time, follow steps one through 5 in the below Ignition section. SECTION 2: IGNITION STEP 6 STEP 1 Your Fire Table is equipped with an auto spark ignition (piezo Ensure that the gas valve knob is in the “OFF”...
  • Page 12: Ignition Troubleshooting

    Once the unit is burning normally set the dial to desired flame height. WARNING: Never handle glass rocks which have not been allowed to cool from exposure to flame. Never attempt to rearrange rocks while unit is ignited. En-11 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 13 SECTION 2: IGNITION (continued) STEP 8 PERIODIC INSPECTION OF BURNER FLAMES If there are no flames present, Upon igniting the appliance, as demonstrated in the image visually verify that the to the left, the appliance is likely burner is indeed burning as not burning.
  • Page 14 En-13 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...
  • Page 15: Year Limited Warranty

    Any returns sent back to FMI Brands must be sent via prepaid freight and in the original retail packaging. Please register your OUTLAND Living product for proof of purchase and warranty at http://outlandliving.com/register-products/ For more warranty information and details please contact FMI Brands Inc.
  • Page 16 Owner & Safety Manual En-15 OUTLAND LIVING FIRE TABLE OWNER & SAFETY MANUAL ™ D.410.000.V0...

This manual is also suitable for:

Fmppc2e-1

Table of Contents