Suzuki RGV250 1989 Manual page 20

Hop up kit
Table of Contents

Advertisement

CARBURETOR JETTING EXAMPLE (# 1 indicates the left cylinder and # 2 the right.)
FOR STAGE I
MJ
NJ
JN
PJ
MAJ
PWJ
AS
# 1
# 3 2 0
0 - 9
6FL-76-52-3
35
0.5
60
1% Turns back
# 2
# 3 2 0
0 - 9
6FL-76-52-3
35
0.5
60
1% Turns back
FOR STAGE H
MJ
NJ
JN
PJ
MAJ
PWJ
| AS
# 1
# 3 4 0
P-1
6FL-76-52-3
35
0.5
60
1% Turns back
# 2
# 3 5 0
P-1
6FL-76-52-3
35
0.5
60
1% Turns back
Atmospheric temperature: 10°C;
Barometric pressure
For high speed circuit
: 760mmHg.
: Change with larger
MJ 2 - 3 sizes.
Change with larger
NJ by 1 - 2 sizes.
Atmospheric temperature: 10°C;
Barometric pressure
: 755 mmHg
For high speed circuit
Change with larger
MJ 2 - 3 sizes.
Change with larger
NJ by 1 size.
If aviation gasoline is mixed, the jetting may
be altered from the above charts as indicated
below:
With 50% of mixture
If with MJ, smaller by 1 size
100% avgas
If with MJ, smaller by 2 sizes
- 1 7 ™