Only connect computer-related elements to the UPS unit.
DO NOT CONNECT medical applications or life-support equipment.
DO NOT CONNECT AS WELL laser printer, labelling machines, copy machines, generators, vacuum cleaners, drain
pumps, microwave ovens or other larger electric appliances to the output connectors. The electricity consumption
would cause an overload and possibly even the damage of the UPS.
To reduce the risk of overheating: do not cover or block the vent of the UPS unit, do not expose the appliance to
direct sunlight, do not install it near heat emitting appliances such as space heaters or furnaces/ovens.
Pull the mains plug out of the socket before cleaning. Do not use liquid or spray detergents.
Do not expose the batteries to fire because they may explode.
Do not open and/or damage the batteries on their outside: released electrolyte (lead-acid-accumulator) is harmful
to skin and eyes. It may be toxic.
A battery holds the risk of electric shocks and short circuits. The following precautions should be considered when
working with batteries:
1) Remove watches, rings or other metal objects from your hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and rubber boots.
4) Do not deposit tools and/or metal parts on the battery.
5) Disconnect the appliance from the mains each time you are connecting or disconnecting the battery terminals.
The maintenance of the batteries should be executed by battery-knowledgeable personnel. Observe the
recommended and necessary precautions. Keep unauthorised personnel away from the batteries.
When the batteries are replaced, utilize the same quantity and type of sealed lead-acid battery. The ambient
temperature may not exceed 40°C. For maintaining the battery lifetime, we advise an ambient operating
temperature of 20°C to 25°C.
Ensure during the installation of the appliance, that the sum of the residual current of the UPS and of the
connected load does not exceed 3.5mA.
Caution of electric shocks. Even when the unit is disconnected from the mains, dangerous voltages could be
achieved via power supply from the battery. For that raison, interrupt the battery on its plus and minus poles
when maintenance and servicing activities are necessary and undertaken.
The mains socket outlet that supplies the UPS shall be installed near the UPS unit and shall be easily accessible.

3. SPECIFICATIONS

LED Model
& LCD Model
Capacity
Input
Voltage
Voltage range
Frequency range
Output
Voltage in battery mode
Frequency in battery mode
Transfer time
Batteries
Recharge time
Number and type of battery
LED Indicator
Mains mode (AC)
Battery-Modus
Protection
Overvoltage / overload
Audible alarm
Battery mode
Weak autonomy
Overload
Replace batteries
Fault
Size ratio
Dimensions – mm (W x D x H)
Net weight – kg
3
BP650
BP850
BP650D
BP850D
650VA
850VA
60/50 Hz (automatic recognition)
230 Vac ±10% (no block sinus)
6-8 hours to reach 90% of capacity
1 x 12V7Ah
1 x 12V9Ah
green and orange LED lighting
101 x 298 x 142
4.25
4.9
BUDGET PRO series 650-2200VA - UPS
BP1100
BP1300
BP1100D
BP1300D
1100VA
1300VA
220 / 230 / 240 Vac
162-290 Vac
50/60 Hz ±1%
typically : 2 à 6 ms
2 x 12V7Ah
2 x 12V7Ah
green LED lighting
surge protection
sounding every 10s
sounding every 1s
sounding every 0.5s
sounding every 2s
continuously sounding
149.3 x 338 x 162
7.8
8
BP1600
BP2200
BP1600D
BP2200D
1600VA
2200VA
2 x 12V9Ah
2 x 12V9Ah
158 x 380 x 198
11.1
11.5
www.visionups.com