    User Manual Vision Spirit II G XL 6-10KVA – 3/1 phase PF0.9 True online double conversion UPS...
  • Page 2 All rights reserved. The information in this document is subject to change without notice. Thank you for purchasing this series UPS. This series UPS is an intelligent, three phase in single phase out, high frequency online UPS designed by our R&D team who is with years of designing experiences on UPS. With excellent electrical performance, perfect intelligent monitoring and network functions, smart appearance, complying with EMC and safety standards, This UPS has become standard product which meets the world’s advanced level.
  • Page 3: Table Of Contents

    Contents 1.SAFETY ..............................- 2 - 1.1 Safety notes............................ - 2 - 1.2 Symbols used in this guide......................- 2 - 2.MAIN FEATURES ..........................- 3 - 2.1 Summarization..........................- 3 - 2.2 Functions and features ......................- 3 - 3.INSTALLATION ...........................
  • Page 4: Safety

    1.Safety Important safety instructions – Save these instructions There exists dangerous voltage and high temperature inside the UPS. During the installation, operation and maintenance, please abide the local safety instructions and relative laws, otherwise it will result in personnel injury or equipment damage. Safety instructions in this manual act as a supplementary for the local safety instructions.
  • Page 5: Main Features

    2.Main Features 2.1 Summarization This series UPS is a kind of three phase in single phase out high frequency online UPS, it provides two capacities: The 6kVA and 10kVA. The products are modularized and adopt the N+X redundancy. It can flexibly increase the number of the UPS modules according to the load capacity which is convenient for flexible allocation and gradually investment.
  • Page 6: Installation

    3.Installation 3.1 Unpack checking 1. Don’t lean the UPS when moving it out from the packaging. 2. Check the appearance to see if the UPS is damaged or not during the transportation, do not switch on the UPS if any damage found. Please contact the dealer right away. 3.
  • Page 7: Lcd Control Panel

    Side View (1) handles (2) fixing screw hole (3) LCD Display (4) Intelligent slot (5) EPO (6) COM (RS232)(7) Parallel Port 1 (8) USB port (9) Parallel Port 2 (10) Output terminal (11) Output breaker (12) Battery Slot (13) Output IEC (14) PDU (15) Input breaker (16) Input terminal 3.3 LCD control panel 开机...
  • Page 8: External Protective Devices

    temperature, a system of room extractor fans is recommended to be installed. Optional air filters are available if the UPS operates in a dusty environment. ◆ The environment temperature around the UPS should keep in a range of 0℃~40℃. If the environment temperature exceeds 40℃, the rated load capacity should be reduced by 12%...
  • Page 9: Power Cables

    over-current through a DC compatible thermo-magnetic circuit-breaker (or a set of fuses) located close to the battery. ◆ UPS Output Any external distribution board used for load distribution shall be fitted with protective devices that may avoid the risk of UPS overloaded. ◆...
  • Page 10: Power Cable Connect

    WARNING! FAILURE TO FOLLOW ADEQUATE EARTHING PROCEDURES MAY RESULT IN ELECTROMAGNETIC INTERFERENCE OR IN HAZARDS INVOLVING ELECTRIC SHOCK AND FIRE 3.7 Power cable connect Once the equipment has been finally positioned and secured, connect the power cables as described in the following procedure. Verify the UPS is totally isolated from its external power source and also all power isolators of the UPS are open.
  • Page 11 of the 8 ) and the anode of the 9 ) of the batteries. Then the neutral, the battery positive and the battery negative are connected with the UPS respectively. The battery sets between the Battery anode and the neutral are called positive batteries and that between neutral and cathode are called negative ones.
  • Page 12: Ups Multi-Module Installation

    WARNING! Ensure correct polarity of string end connections to the Battery Circuit Breaker and from the Battery Circuit Breaker to the UPS terminals i.e. (+) to (+) / (-) to (-) but disconnect one or more battery cell links in each tier. Do not reconnect these links and do not close the battery circuit breaker unless authorized by the commissioning engineer.
  • Page 13: Parallel Cable Installation

    3.9.2 Parallel cable installation Shielded and double insulated control cables available must be interconnected in a ring configuration between UPS modules as shown below. The parallel control board is mounted on each UPS module. The ring configuration ensures high reliability of the control. 3.9.3 Requirement for the parallel system A group of paralleled modules behave as one large UPS system but with the advantage of presenting higher reliability.
  • Page 14: Operation

    3) The outputs of all the UPS modules must be connected to a common output bus. 4) The length and specification of power cables including the bypass input cables and the UPS output cables should be the same. This facilitates load sharing when operating in bypass mode.
  • Page 15: Turn On/Off Ups

    4.2 Turn on/off UPS 4.2.1 Connecting with Utility CAUTION! MAKE SURE GROUNDING IS PROPERLY DONE! ◆ Set the Battery Breaker to the “ON” position according to the user’s manual. ◆ Switch on the UPS CAUTION! Check to see if the load is safely connected with the output of the UPS. If the load is not ready to receive power from the UPS, make sure that it is safely isolated from the UPS output terminals The internal fan of the UPS starts spinning, the UPS is performing self-diagnostics...
  • Page 16: Inverter Off

    CAUTION! Wait for approximately 30 seconds before you press the black start key. 4.2.3 Inverter Off When the Utility is normal, press “Off” button for approx. 1 sec until beep sounds, the inverter LED will extinguish, the bypass LED on, then the UPS turns to bypass supply.
  • Page 17 2) Press ESC/ ◀ or ▶ button, it will change to the basic status interface (see Fig 2 below). MODE:ONLINE Volt: BN CN Vin: 220 220 220 Vout:220V 50HZ Fig.2:Basic status interface 3) Press the ENT button, it will change to main menu (see Fig 3). FIGUER STATUS SETTING...
  • Page 18: Working Mode And Transferring

    6) Select and confirm the status info can view the details, including status information, alarm information, code, power rating and version (see Fig 13 to 14). STATUS STATUS Code:11 Version V03B05D002 Fault :0. 0.0.0 Model:06.0KVA Fig.13:main menu Fig.14:main menu 7) Select and confirm setting menu, setting information will be displayed on the screen, which includes user set, system set, parallel set, battery sett, revise set (see Fig 15 to 19).
  • Page 19: Normal Mode To Battery Mode

    transfer to bypass mode and beeps twice every second, then the load is powered by AC directly. Please decrease the load immediately until the alarm is eliminated. The UPS will start the inverter after 5 min. In order to protect the load and the UPS, it is required to set the limitation times of transferring to bypass mode due to overload in 1 hour.
  • Page 20 button to change the value and press ENT to confirm it. Once confirmed, it will not be highlighted. 4) Press the arrow button can view the detailed alarm info after entering the alarm info interface, press the ESC to return to main menu. 3 Priority of info displayed on LCD 1) I f there is alarm but no valid operation on buttons, the alarm info with top priority will be shown on LCD automatically.
  • Page 21: Maintenance

    5.Maintenance Please follow the installations notes under section 3.4. to install the UPS. 5.1 Ventilator maintenance The continuous operating time of fan is 20000 to 40000 hours. This time will be shorten if the temperatures increases. Please check the fan periodically and ensure that it blows wind out. 5.2 Battery maintenance Inside the series standard models are maintenance free, sealed lead acid batteries.
  • Page 22: Function Control

    5.5 Function control Check the functions every 6 months. 1) Press the OFF-key to determine if buzzer, indicators and LCD-display are operating normally or not. Refer for that to section «4.1 Operation modes». 2) Press the ON-key, check indicators, LCD-display and inverter of the UPS. Assure yourself, that they are all operating normally.
  • Page 23 Rating Frequency 50Hz/60Hz Frequency track speed 1Hz/s 105%~110%,1Hr 110%~125% 10min Overload 125%~150% 1min ≥150% 200ms Peak value factor ≥90% Efficiency at normal 5.0% Dynamic respond 20ms ≤500mV DC heft Between Normal mode and battery mode Between inverter and bypass unlock:<15ms (50Hz), <13.33ms (60Hz) <55dB (1m)...
  • Page 24: Appendix 2 Communication Port Definition

    Appendix 2 Communication port definition USB communication port: Definition of male port: Pin 1 VCC, Pin 2 D- pin 3 D+, Pin 4 GND Application: use UPSilon2000 Power Management software Available functions of the USB ■ Monitor UPS power status ■...
  • Page 25: Appendix 4 Ups Message Table

    Appendix 4 UPS message table This section lists the event and alarm messages that the UPS might display. The messages are listed in alphabetical order. This section is listed with each alarm message to help you troubleshoot problems. 4.1 Operational Status and Mode(s) Note:“X”...
  • Page 26 Item UPS Alarm Warning Buzz Rectifier Over Temperature Twice per second Fault LED lit Inverter Over temperature Twice per second Fault LED lit Reserve Twice per second Fault LED lit Battery reverse Twice per second Fault LED lit Cable connection error Twice per second Fault LED lit CAN comm.