Connection
5.6 Analog X3 inputs/outputs
Pin assignment
Table 5- 13
Pin
1
2
3
4
5
6
7
8
9
10
11
12
The analog signal to be measured is connected to the terminals AI 1+/- and AI 2+/-. AI
stands for "Analog Input". The CO "Current Output" and CI "Current Input" terminals supply
the constant current for the 4-wire measurement of PT100 elements.
Analog inputs
The module has two analog inputs. These can optionally be assigned parameters as voltage,
current or PT100 input.
NOTICE
The analog inputs are only enabled following the parameter assignment.
Cycle time of the analog value accumulation: 20 ms per channel
Table 5- 14
Parameter
Input range (rated value)
permitted overrange
Resolution
Accuracy
Internal resistance Ri
32
X3 pin assignment
Signal name
Signal type
CO1
O
CI1
I
AI1+
I
AI1-
I
CO2
O
CI2
I
AI2+
I
AI2-
I
AO3+
O
AO3-
O
AO4+
O
AO4-
O
Technical specifications in the "voltage input" operating mode
Meaning
Channel 1 current output for PT100
Channel 1 current input for PT100
Channel 1 analog input +
Channel 1 analog input -
Channel 2 current output for PT10
Channel 2 current input for PT100
Channel 2 analog input +
Channel 2 analog input -
Channel 3 current and voltage output +
Channel 3 current and voltage output -
Channel 4 current and voltage output +
Channel 4 current and voltage output -
Value
- 10 V to + 10 V
- 11.75 V to + 11.75 V
16 bits (including sign)
+/- 0,5 %
100 KOhm
PP 72/48D 2/2A PN I/O module
Manual, 03/2010