  • Page 1 Original instructions AGI4500/6000 ..24 ..31 ..27 ..18 ..21 ..39 ..47 ..35 ..43 ..51...
  • Page 2 AGI4500/6000 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
  • Page 3: Horizontal Mounting

    AGI4500/6000 AGI4500 Horizontal mounting 255 195 185 245 1,5 m: 4 x M10 2, 2,5, 3 m: 6 x M10 [mm] AGI4515 1500 2000 AGI4520 AGI4525 2500 DN25 (1"), inside thread AGI4530 3000 Vertical mounting Fig.1a...
  • Page 4 AGI4500/6000 AGI6000 Horizontal mounting 101,5 56,5 1,2; 1,8 m; 2,4 m: 6 x M10 3 m: 10 x M10 [mm] AGI6012 1200 AGI6018 1800 AGI6024 2400 AGI6030 3000 Inside thread AGI6012/6018/6024: DN25 (1") AGI6012 AGI6012 AGI6018 AGI6018 AGI6030: DN32 (1 1/4")
  • Page 5 AGI4500/6000 AGI6000 Vertical mounting [mm] AGI6012 1200 AGI6018 1800 2400 AGI6024 AGI6030 3000 Inside thread AGI6012/6018/6024: DN25 (1") AGI6030: DN32 (1 1/4") Fig.1c...
  • Page 6 AGI4500/6000 13.2X4 [mm] [mm] [mm] [mm] AGI4500 AGI6000 Fig. 2. Floor frame 300 mm Fig. 3. Minimum distance...
  • Page 7 AGI4500/6000 Accessories DBS10-4 AGIH4515 DBS10-6 AGIH4520/4525/4530 GP1010 AGIH6000 AXP500 AGIV GP1010 AGIH6012/6018/6024 6 pcs AGIH6030 10 pcs GP1010 AXP500 Controls Level 1 RTRD3 RTRD5.2 RTRD7 RTRD14 RTRDU7 RTRD3/5.2/7 RTRD14 AGB304 T10S T10S (AGI W) RTI2 AGB304 Level 2 MDCDC RTI2 RTRDU VRS20 DN20...
  • Page 8: Agi4515

    AGI4500/6000 AGI4500/6000 A 400V3N~ L2 L3 U1 V1 W1 RT RT N L L TK TK FS FS Bridge RT-RT if no door contact is used. RTRD To terminals To terminals L1, L2 and 5-6 in slave L3 in slave units.
  • Page 9: Agi4520

    AGI4500/6000 AGI4500/6000 W Level 1 Bridge RT-RT if no door contact is used. 400V3N~ T10S TVVS20/25 L2 L3 U1 V1 W1 RT RT N L L TK TK FS FS SD20 RTRD KRT1900 To terminals 230V~ L1, L2 and To terminals L3 in slave 5-6 in slave units.
  • Page 10: Agi4525

    AGI4500/6000 AGI4500/6000 W Level 2 230V~ 230V~ 400V3N~ SD20 RTRDU TVVS20/25 RTI2 To terminals L1, L2 and To terminals L3 in slave 5-6 in slave units. units. Number of fans AGI4515/AGI6012 AGI4520/AGI6018 AGI4525/AGI6024 AGI4530/AGI6030...
  • Page 11 AGI4500/6000 AGI4500/6000 230V3~ -connected - only for 230V3~ Convertible 400V3~ / 230V3~...
  • Page 12 – = at the current water temperatures and airflows, the air outlet temperature will be less than 35 °C. ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 13 AGI4525WH Max 9100 0,27 41,7 1,62 26,7 AGI4530WH Max 10900 0,34 41,8 1,95 27,8 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 14: Agi6018

    728,4 49,6 29,6 0,60 AGI6024WL 15600 88,3 50,0 4,76 126,1 62,7 29,8 0,76 AGI6030WL ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 15: Agi6030

    90,8 39,1 2,02 54,2 AGI6030WH Max 15600 89,7 54,0 0,78 114,3 39,5 2,55 34,9 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 16 AGI4500/6000 Technical specifications AGI4500 Ambient, no heat - AGIH4500 A Horizontal mounting (IP54) Type Output Airflow Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] AGIH4515A 5500 400V3~ 1500 7300 400V3~ 2000 AGIH4520A AGIH4525A 9100 400V3~ 2500...
  • Page 17 AGI4500/6000 Technical specifications AGI6000 Ambient, no heat - AGIH6000 A Horizontal mounting (IP54) Type Output Airflow Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] AGIH6012A 6600 400V3~ 1200 AGIH6018A 9600 400V3~ 1800 AGIH6024A...
  • Page 18 Recommended installation height AGI4500: 4,5 m and AGI6000: 6 m. The air curtain is available Electrical installation without heat and with water heating. The installation, which should be preceded by Protection class: IP54.
  • Page 19: Maintenance

    AGI4500/6000 Fan replacement (when the premises are heated and the outdoor air is cold). 1. Determine which of the fans is not The air stream should therefore be directed functioning. outwards to withstand the load. Generally 2. Disconnect the cables to the relevant fan. speaking, the higher the load, the greater the 3.
  • Page 20 AGI4500/6000 Safety • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • The unit may have hot surfaces during operation and when cooling down! • Lifting equipment must be used to lift the unit. •...