GB
.... 18
ES
NL
.... 35
All manuals and user guides at all-guides.com
NO
.... 24
.... 21
.... 39
IT
.... 43
Original instructions
AGI4500/6000
FR
.... 27
PL
.... 47
DE
.... 31
RU
.... 51

Advertisement

loading
Need help?

Need help?

Do you have a question about the AGI4500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Frico AGI4500

  • Page 1 All manuals and user guides at all-guides.com Original instructions AGI4500/6000 ..24 ..31 ..27 ..18 ..21 ..39 ..47 ..35 ..43 ..51...
  • Page 2 All manuals and user guides at all-guides.com AGI4500/6000 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages.
  • Page 3: Horizontal Mounting

    All manuals and user guides at all-guides.com AGI4500/6000 AGI4500 Horizontal mounting 255 195 185 245 1,5 m: 4 x M10 2, 2,5, 3 m: 6 x M10 [mm] AGI4515 1500 AGI4520 2000 AGI4525 2500 AGI4530 3000 DN25 (1"), inside thread Vertical mounting Fig.1a...
  • Page 4 All manuals and user guides at all-guides.com AGI4500/6000 AGI6000 Horizontal mounting 101,5 56,5 1,2; 1,8 m; 2,4 m: 6 x M10 3 m: 10 x M10 [mm] AGI6012 1200 AGI6018 1800 2400 AGI6024 AGI6030 3000 Inside thread AGI6012/6018/6024: DN25 (1")
  • Page 5 All manuals and user guides at all-guides.com AGI4500/6000 AGI6000 Vertical mounting [mm] AGI6012 1200 AGI6018 1800 AGI6024 2400 AGI6030 3000 Inside thread AGI6012/6018/6024: DN25 (1") AGI6030: DN32 (1 1/4") Fig.1c...
  • Page 6 All manuals and user guides at all-guides.com AGI4500/6000 13.2X4 [mm] [mm] [mm] [mm] AGI4500 AGI6000 Fig. 2. Floor frame 300 mm Fig. 3. Minimum distance...
  • Page 7 All manuals and user guides at all-guides.com AGI4500/6000 Accessories DBS10-4 AGIH4515 DBS10-6 AGIH4520/4525/4530 GP1010 AGIH6000 AGIV AXP500 GP1010 AGIH6012/6018/6024 6 pcs AGIH6030 10 pcs GP1010 AXP500 Controls Level 1 RTRD3 RTRD5.2 RTRD7 RTRD14 RTRDU7 RTRD3/5.2/7 RTRD14 AGB304 T10S T10S (AGI W)
  • Page 8 All manuals and user guides at all-guides.com AGI4500/6000 AGI4500/6000 A 400V3N~ L2 L3 U1 V1 W1 RT RT N L L TK TK FS FS Bridge RT-RT if no door contact is used. RTRD To terminals To terminals L1, L2 and...
  • Page 9 All manuals and user guides at all-guides.com AGI4500/6000 AGI4500/6000 W Level 1 Bridge RT-RT if no door contact is used. 400V3N~ T10S TVVS20/25 L2 L3 U1 V1 W1 RT RT N L L TK TK FS FS SD20 RTRD KRT1900...
  • Page 10 All manuals and user guides at all-guides.com AGI4500/6000 AGI4500/6000 W Level 2 230V~ 230V~ 400V3N~ SD20 RTRDU TVVS20/25 RTI2 To terminals L1, L2 and To terminals L3 in slave 5-6 in slave units. units. Number of fans AGI4515/AGI6012 AGI4520/AGI6018 AGI4525/AGI6024...
  • Page 11 All manuals and user guides at all-guides.com AGI4500/6000 AGI4500/6000 230V3~ -connected - only for 230V3~ Convertible 400V3~ / 230V3~...
  • Page 12 – = at the current water temperatures and airflows, the air outlet temperature will be less than 35 °C. ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 13 AGI4525WH Max 9100 0,27 41,7 1,62 26,7 AGI4530WH Max 10900 0,34 41,8 1,95 27,8 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 14 7,89 728,4 49,6 29,6 0,60 AGI6030WL 15600 88,3 50,0 4,76 126,1 62,7 29,8 0,76 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 15 90,8 39,1 2,02 54,2 AGI6030WH Max 15600 89,7 54,0 0,78 114,3 39,5 2,55 34,9 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 16 All manuals and user guides at all-guides.com AGI4500/6000 Technical specifications AGI4500 Ambient, no heat - AGIH4500 A Horizontal mounting (IP54) Type Output Airflow Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] AGIH4515A 5500...
  • Page 17 All manuals and user guides at all-guides.com AGI4500/6000 Technical specifications AGI6000 Ambient, no heat - AGIH6000 A Horizontal mounting (IP54) Type Output Airflow Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] AGIH6012A 6600...
  • Page 18 The air curtain doorways such as logistic centres, loading must be secured to wall or ceiling. bays and warehouses. Recommended installation height AGI4500: 4,5 m and AGI6000: 6 m. The air curtain is available Electrical installation without heat and with water heating.
  • Page 19 All manuals and user guides at all-guides.com AGI4500/6000 Fan replacement (when the premises are heated and the outdoor air is cold). 1. Determine which of the fans is not The air stream should therefore be directed functioning. outwards to withstand the load. Generally 2.
  • Page 20 All manuals and user guides at all-guides.com AGI4500/6000 Safety • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • The unit may have hot surfaces during operation and when cooling down! • Lifting equipment must be used to lift the unit.
  • Page 21 All manuals and user guides at all-guides.com Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...