Figure 42. Riser for slots 10 through 15 (right riser) installation
Step 1.
Align the riser with the I/O tray and insert it; then, press the riser into the I/O tray until the connector
is fully seated.
Step 2.
Tighten the two captive screws (items 4 in preceding figure) that secure the riser to the I/O tray
board.
If you have no other options to install in the I/O tray after installing the riser for slots 10 through 15, install the
I/O tray in the chassis. See "Install the I/O tray" on page 153.
Install a riser bracket for slots 14 and 15
The riser bracket for slots 14 and 15 is attached to the slot 10 through 15 I/O tray riser that is accessed from
the rear of the server. After removing the I/O tray and the riser for slots 10 through 15 (right riser), slide the
bracket onto the riser until the retaining clips engage.
S002
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off the
electrical current that is supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
.
Chapter 3
Server hardware setup
77