Important: You must remove the riser from the I/O tray before installing an adapter.
Complete the following steps to install a LOM adapter in slot 9.
Watch the procedure. A video of the installation process is available:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-DbSYJFY74PoKmph7vgrkKH&playnext=1
• Youku:
http://list.youku.com/albumlist/show/id_50952215
Figure 66. LOM adapter installation (slot 9)
Step 1.
Attach the extension bracket to the top of the LOM adapter using two screws.
Step 2.
Align the adapter with I/O-tray slot 9 and insert it; then, press the adapter into the I/O tray until the
connector is fully seated.
Step 3.
Tighten the captive thumbscrew on the side of the LOM adapter that secures it to the bracket on
the I/O tray.
If you have no other operations to perform on the I/O tray after installing a LOM adapter in slot 9:
1. Install the riser for slots 10 through 15 (right riser). See "Install the riser for slots 10 through 15 (right
riser)" on page 177.
2. If any of the adapters in the I/O tray have internal cables, make sure that they are connected before
installing the I/O tray.
3. Install the I/O tray in the chassis and connect all cables. See "Install the I/O tray" on page 153.
Install a PCIe adapter in slots 10 through 15
PCIe adapters in slots 10 through 15 are in an I/O tray riser that is accessed from the rear of the server. With
the riser removed from the I/O tray, open the retention latch and insert the adapter in the riser; then, close the
retention latch.
S002
CAUTION:
120
ThinkSystem SR950 Setup Guide