Checking and Adjusting the
Traction Cable
Service Interval: After the first 2 hours—Inspect
the traction cable and adjust it if
necessary.
Yearly—Inspect the traction cable and adjust or
replace it if necessary.
If the machine does not drive in the forward or reverse
speeds or it drives when you release the traction lever,
adjust the traction cable.
If the left (traction) cable is not properly adjusted, do
the following steps:
1.
Loosen the jam nut.
2.
Engage the traction lever and hold it in place
(Figure
32).
Figure 32
3.
Loosen or tighten the turnbuckle to adjust the
spring length to 5.5 cm (2.18 inches) as shown
in
Figure
33.
1. Jam nut
2. Turnbuckle
4.
Tighten the jam nut
is slight tension on the cable.
5.
If the traction cable is properly adjusted but a
problem remains, contact an Authorized Service
g001011
Dealer.
Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Loosen the jam nut.
2.
Engage the auger/impeller lever and hold it in
place
(Figure
18
Figure 33
3. Spring
4. 5.5 cm (2.18 inches)
(Figure
33), ensuring there
auger/impeller cable and adjust it if
necessary.
34).
Figure 34
g030998
g001013