P01
Manufacturer information
Gas used
P02
00 = METHANE - 01 = LPG
Hydraulic system
00 = instantaneous appliance
P03
05 = appliance with external storage boiler
08 = heating only appliance
Programmable relay 1 settings (See SERVICE instructions)
00 = no associated function
01 = relay contact closed with Room Thermostat demand (230V)
02 = relay contact closed with Remote Control demand (low voltage)
03 = system fill contact
04 = boiler faulty signal contact
P04
05 = fan contact (kitchen fan)
06-07 = not used
08 = timed contact for enabling external DHW pump
09 = timed contact for enabling external DHW circulation pump via DHW programming from
remote control
10 = relay contact closed with DWH demand active
11 - 12 - 13 = not used
Programmable relay 2 settings
P05
d
NOT MODIFY (
edicated to automatic filling )
External probe input configuration
P06
(See SERVICE Instructions)
P07..P09 Manufacturer information
Heating setpoint setting OT / RT
(Remote Control - Open Therm / Room Thermostat 230V~)
00 = the temperature request is the Remote Control setpoint
01 = not used
02 = the temperature request is the Remote Control setpoint. The Room Thermostat enable
the gas boiler operates.
P10
03 = the calculated setpoint depends on the origin of the request (PCB or Remote Control):
a) PCB (Ambient Thermostat): the setpoint is set by pressing the +/-
boiler control panel, after having first disconnected the Remote Control from the boiler.
b) Remote Control: the setpoint is set by modifying the "CH SL" parameter (see chapter
"ELECTRICAL CONNECTIONS - INSTALLER FUNCTIONS")
c) Simultaneous request PCB - Remote Control the higher setpoint of the two requests is
satisfied.
P11..P12 Manufacturer information
P13
Max. heating output (0-100%)
P14
Max DHW output
P15
Min. heating output (0-100%)
Maximum CH setpoint (°C)
P16
00 = 85°C - 01 = 45°C
P17
Pump overrun time in heating mode (01-240 minutes)
Delay prior to new ignition in CH mode
P18
(00-10 minutes) - 00=10 seconds
P19
Manufacturer information
P20
Pump overrun time in DHW mode (seconds)
Anti-legionellosis function (°C) 00...54 = Disabled - 55...67 = Enabled
P21
(set the desired temperature value)
P22
Manufacturer information
P23
Maximum DHW setpoint temperature (ACS)
P24
Manufacturer information
P25
No water safety device
P26..P31 Manufacturer information
P32..P41 Diagnostics (See SERVICE Instructions)
Open Therm (OT) settings (See SERVICE
P67
00 = Plug & Play
7689490.01 (1-09/17)
DESCRIPTION OF PARAMETERS
(0-100%)
Instructions)
buttons on the
26
FACTORY SETTINGS
1.12
1.24
24
28
00
00
08
08
00
00
02
03
00
--
00
--
100
100
80
86
100
00
00
03
03
07
30
00
00
60
35
00
--
--
00