15. PARAMETERS SETTING
Set the parameters at the control panel in the boiler control box. To access this, refer to the chapter "ELECTRICAL
CONNECTIONS".
Key to BUTTONS
DHW temperature adjustment
(+ to increase the temperature and – to decrease it)
Heating water temperature adjustment
(+ to increase the temperature and – to decrease it)
Boiler operating information
Operating mode:
DHW – DHW & Heating – Heating Only
Off – Reset – Exit menu/functions
Key to SYMBOLS
Off: heating and DHW disabled
(only boiler anti-freeze protection is active)
Fault preventing the burner from lighting
Boiler/system water pressure low
Technical Service Centre call-in
Manually resettable fault (
Fault in progress
To programme the parameters of the boiler electronic board, proceed as follows:
• Press
and
together and hold them down for 6 seconds until programme row "P01" appears on the display alternated
with the set value;
• Press
to scroll the list of parameters;
• Press
the value of the selected begins flashing, press
• Press
to confirm the value or press
Further information concerning the parameters listed in the following table are supplied together with the required
accessories.
)
to change the value;
to exit without saving.
25
Burner lit
DHW operating mode enabled
Heating mode enabled
Programming menu
Boiler information menu
Set unit of measurement (SI/US)