11.1 INSTALLING THE REMOTE CONTROL ON THE WALL

Before mounting the accessory, consult the Room Unit manual.
Proceed as follows:
• Disconnect the boiler from the mains power supply.
• Remove the jumper from the ends of the contacts 1-2 of the
terminal block M1.
• Open the Remote Control, separating the base B from the front
panel A.
• Pass the two wires from the boiler terminal block M2 through the
hole in the base B to apply to the wall.
• Connect wires 1-2 (non-polarised) of the boiler terminal block M2
to the ends of the terminal of the base B.
• Fix the base B to the wall using the expansion plugs and screws
supplied with the accessory.
• Apply the front panel A to the base fixed to the wall, taking care
not to apply excessive force.
• Power the boiler making sure that the Remote Control lights
up.
The Room Unit controls the boiler with the exception of the Flue Cleaner Function, the Initial Start-up Function and the
Combustion Adjustment Function. The Boiler Information menu is not available on the Room Unit.
If the error code "E83" is displayed there is a communication fault between the main board and the Control Unit. Probable
short circuit on wiring. Avoid placing cables near sources of heat, high voltage and magnetic fields.
11.1.1 INSTALLER FUNCTIONS
To access the Information and Advanced Setting mode, it is necessary to press, for at least 3 seconds, the IP button;
in INFO mode the display shows "INFO".
To escape the INFO mode briefly press the IP button.
In this mode press the OK button to scroll the windows; to set parameters press the +/-
Communications between the main board and the remote control is not immediately. In some case it may happen that the
command given through the remote control takes some time depending on the type of the transferred information.
CENTRAL HEATING (CH)
• "CH SL" Max. heating circuit setpoint, value settable with the buttons +/-
°C to °F and vice versa, press the
• "EXT°c" Outside temperature (with external sensor connected).
• "CH O>" Maximum Heating flow temperature.
• "CH R<" Return heating temperature (unplanned).
• "CH S^" CH temperature setpoint.
• "CH MX" Maximum CH temperature setpoint.
• "CH MN" Minimum CH temperature setpoint.
DOMESTIC HOT WATER (DHW)
• "HW O>" D.H.W. flow temperature.
• "HW S^" Maximum setpoint temperature value setting. Press the +/-
• "HW MX" Maximum D.H.W. temperature setpoint.
• "HW MN" Minimum D.H.W. temperature setpoint.
ADVANCED INFORMATION
• "PWR %" Power level/modulating flame (%).
• "P BAR" Water pressure heating circuit (bar).
• "F L/M" Water flow rate (l/min).
button.
19
M2
1
2
3
4
5
6
7
8
B
C
button.
. WARNING: to change the unit of measure from
buttons to set the value.
7689490.01 (1-09/17)
9
10
A
CG_2586