7.6.9 Exit communication mode
... „XT" ...
answer:
ACK = executed
NAK = Error

7.7 Parameter changing commands

7.7.1 Change parameters
In the operation mode database/PC of the reader it is also possible to change
some parameter of the reader itself e.g. reading time, switch off time etc.
This is done by the command „s":
Format:
STX, „s" , „Address = 3xASCII-chr", „Value = 2xASCII-chr " , „crc =
4xASCII-chr" , ETX.
Address Name
0x004
Set code
format
0x00E
Turn-off
time
0x00F
Turn-on
delay
0x010
Reading
time
0x011
Baudrate
0x012
Keyboard
---------------------------------------------------------------39/51---------------------------------------
Options/Values
Representation of ISO-Codes:
0x00 : hexadecimal
0x01 ISO animal
0x02 ISO industry
Time until the device will automatically shut
off.
Set in 5 second steps
(Parameter 0xFF=the device
didn't switch off)
The time the main-button is to be pressed to
switch on the reader.
value*0.5s
Sets the time frame for one reading attempt
Value*500ms
0x01 = 9600 Baud
0x02 = 19200 Baud
0x03 = 38400 Baud
Activates the Keyboard sounds
Parameter-
Default
Range
Value
0x00-0x02
0x01
(0-2)
(1)
0x02-0x3C
0x04
(2-60)
(4)
0xFF (255)
0x00-0x0A
0x01
(0-10)
(1)
0x01 – 0x19
0x04
(1 – 25)
(4)
0x01 – 0x03
0x02
(19200)
0x00, 0x01
0x01