Clean the heat-exchanger
•
Open cleaning cover bottom right.
•
Remove ash using ash vacuum cleaner.
Cleaning the temperature detector
•
Dismount left-hand side cover.
•
Open cleaning cover top left.
•
Clean off deposits using a cloth.
Clean air sensor
•
Dismount right-hand side cover.
•
Loosen the fixing screw.
•
Carefully pull the air sensor out of the
holder. The air sensor is a delicate
measuring instrument! If there are dust
deposits, carefully blow off or clean in
distilled water.
•
Carefully and without using force, push the
air sensor with the guide nose into the
holder as far as the stop.
Clean the flue-gas fan
•
Remove the mains plug!
•
Undo the screws of the flue-gas fan.
•
Carefully pull out the motor with the
impeller and clean with a wire brush and
spatula.
•
Remove ash in flue-gas duct using an ash
vacuum cleaner.
19