9 Errors - causes - remedies

Number
Text on display
901
Safety temperature limiter has been triggered
902
Error maximum rpm
903
Error minimum rpm of flue-gas fan undercut
904
Error minimum combustion chamber
temperature undercut
905
Error maximum combustion chamber
temperature exceeded
906
Error maximum circuit board temperature
exceeded
907
Error minimum flow rate undercut
908
Error maximum flow rate exceeded
909
Error maximum chute temperature exceeded
911
Error Maximum ignition time exceeded
912
Error Minimum temperature cool-down time
exceeded
913
Error SD card
914
Error EEPROM
915
Error short circuit rpm measurement
916
Error pallet bin switch open
920
Error flow sensor interruption
921
Error flow sensor short circuit
922
Error combustion chamber temperature sensor
924
Error Chute temperature sensor interruption
925
Error chute temperature sensor short circuit
926
Error circuit board sensor interruption
927
Error circuit board sensor short circuit
928
Error flow rate sensor
933
Error run time userware
934
Error run time firmware
935
Error self-test minimum rpm
936
Error self-test minimum air
937
Error acute air shortage
938
Error extended cool-down phase
939
Error fuel shortage
940
Error external filling run time
941
Notification to clean burn pot and grate
942
Error calibration air sensor MAX
943
Error calibration air sensor MIN
Possible solutions
Check circulator pump
Unlock the safety temperature limiter
(info see 4.3)
Clean heat-exchanger,
clean burn pot, air sensor
Check flue-gas fan, rpm sensor
Check fuel supply
Check pellets (length),
inspect combustion chamber temperature
sensor
Check that heat radiation possible at the back,
replace the circuit board
Check stove cleaning, air sensor;
is the door, ash pan or cleaning cover open?
Inspect the chimney draught
Check cleaning of combustion chamber
(chute),
check circulation pump
Check fuel supply,
check cleaning of burn pot,
check ignition
Check cleaning of stove
Replace the SD card
replace the control panel
Overwrite SD card again
Check flue-gas fan,
check rpm sensor
Close the pellet bin lid
Check room sensor (connection),
replace the sensor(s)
replace the sensor(s)
Inspect combustion chamber temperature
sensor (connection),
replace the sensor(s)
Check chute temperature sensor (connection),
replace the sensor(s)
Replace the sensor(s)
Replace the circuit board
Replace the circuit board
Check sensor,
replace the sensor
Replace the control panel
Replace the control panel
Check flue-gas fan, rpm sensor
Check stove cleaning,
is the door, ash pan or cleaning cover open?
Is the door, ash pan or cleaning cover open?
Check stove cleaning, burn pot
Refill the fuel
Check silo empty, motor jammed
Message after approx. 200 kg pellets
Calibration failed, limit exceeded
Calibration failed, limit undercut
20

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for calimax PWS 0601-A

This manual is also suitable for:

Twist 12Pws 1201-aTwist 6

Table of Contents