AP7050DE
Hardware Installation and Maintenance Guide
Context
Figure 5-15
Figure 5-15 Shielded RJ45 connector and cable
A. Jacket of connector
E. Jacket of Ethernet cable F. Shield layer of Ethernet
Procedure
Step 1 Fit the jacket of the connector onto the Ethernet cable, as shown in
Figure 5-16 Fitting the jacket of the connector onto the Ethernet cable
Step 2 Remove a 30 mm (1.18 in.) long section of the jacket, cut off the nylon twine inside the
jacket, and cut a no more than 5 mm (0.20 in.) cleft in the jacket, as shown in
Issue 01 (2016-04-15)
shows the components of an RJ45 connector and a shielded Ethernet cable.
B. Metal shell of connector
cable
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
C. Wire holder of
connector
G. Twisted-pair wires
Figure
5-16.
5 Appendix
D. Plug of connector
-
Figure
5-17.