Table Of Contents - Toshiba VN-M150HE Installation Manual

Air to air heat exchanger
Hide thumbs Also See for VN-M150HE:
Table of Contents

Advertisement

1-EN
Air to Air Heat Exchanger
Original instruction
Thank you very much for purchasing TOSHIBA Air to Air Heat Exchanger.
Please read this owner's manual carefully before using your Air to Air Heat Exchanger.
• Obtain the "Owner's manual" and "Installation manual" from constructor (or dealer).
Request to constructor or dealer
• Please clearly explain the contents of the Owner's manual and hand over it.
• Read this Installation Manual thoroughly to fully understand everything about your Toshiba Air to Air Heat
Exchanger and be able to install it properly.
• Ask a qualified installer or qualified service person to perform installation.
• System parts such as a wired remote controller (sold separately) are necessary for using this unit.
• After installation, perform a test operation and confirm the safety, then explain to the customer how to use
this unit. Give this installation manual to the customer and ask him/her to keep it with the owner's manual.
Handover to the Customer
• Hand the owner's manual and installation manual to the customer.
• Before the handover, explain fully to the customer the contents of the owner's manual.
Contents
1 Precautions for Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Accessory Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Cautions for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 Separately Sold Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5 Reference Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6 Model List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8 Electric Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
9 Installation Method for Each System Configuration . . . . . . . . . . . . . . . . . . . . . . . . 10
10 Advanced System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11 Advanced Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
12 Test Run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
13 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
14 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
AMP Air Conditioning
- 1 -
Installation Manual
Air to Air Heat Exchanger
Please read carefully through these instructions that contain important information which complies with the
"Machinery" Directive (Directive 2006/42/EC), and ensure that you understand them.
Generic Denomination: Air to Air Heat Exchanger
Definition of Qualified Installer or Qualified Service Person
The Air to Air Heat Exchanger must be installed, maintained, repaired and removed by a qualified installer or qualified service
person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them for you.
A qualified installer or qualified service person is an agent who has the qualifications and knowledge described in the table
below.
Agent
• Qualified installer • The qualified installer is a person who installs, maintains, relocates and removes the Air to Air Heat
• Qualified service
person
Qualifications and knowledge which the agent must have
Exchanger made by Toshiba Carrier Corporation. He or she has been trained to install, maintain,
relocate and remove the Air to Air Heat Exchanger made by Toshiba Carrier Corporation or,
alternatively, he or she has been instructed in such operations by an individual or individuals who have
been trained and is thus thoroughly acquainted with the knowledge related to these operations.
• The qualified installer who is allowed to do the electrical work involved in installation, relocation and
removal has the qualifications pertaining to this electrical work as stipulated by the local laws and
regulations, and he or she is a person who has been trained in matters relating to electrical work on
the Air to Air Heat Exchanger made by Toshiba Carrier Corporation or, alternatively, he or she has
been instructed in such matters by an individual or individuals who have been trained and is thus
thoroughly acquainted with the knowledge related to this work.
• The qualified installer who is allowed to work at heights has been trained in matters relating to working
at heights with the Air to Air Heat Exchanger made by Toshiba Carrier Corporation or, alternatively,
he or she has been instructed in such matters by an individual or individuals who have been trained
and is thus thoroughly acquainted with the knowledge related to this work.
• The qualified service person is a person who installs, repairs, maintains, relocates and removes the
Air to Air Heat Exchanger made by Toshiba Carrier Corporation. He or she has been trained to install,
repair, maintain, relocate and remove the Air to Air Heat Exchanger made by Toshiba Carrier
Corporation or, alternatively, he or she has been instructed in such operations by an individual or
individuals who have been trained and is thus thoroughly acquainted with the knowledge related to
these operations.
• The qualified service person who is allowed to do the electrical work involved in installation, repair,
relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local
laws and regulations, and he or she is a person who has been trained in matters relating to electrical
work on the Air to Air Heat Exchanger made by Toshiba Carrier Corporation or, alternatively, he or she
has been instructed in such matters by an individual or individuals who have been trained and is thus
thoroughly acquainted with the knowledge related to this work.
• The qualified service person who is allowed to work at heights has been trained in matters relating to
working at heights with the Air to Air Heat Exchanger made by Toshiba Carrier Corporation or,
alternatively, he or she has been instructed in such matters by an individual or individuals who have
been trained and is thus thoroughly acquainted with the knowledge related to this work.
www.ampair.co.uk | sales@ampair.co.uk
2-EN
Installation Manual

Advertisement

Table of Contents
loading

Table of Contents