Chauvin Arnoux F07 User Manual

Chauvin Arnoux F07 User Manual

Clamp-on multimeter
Hide thumbs Also See for F07:
Table of Contents

Advertisement

Quick Links

F07
CLAMP-ON MULTIMETER
GlobalTestSupply
www.
.com
Quality AEMC Products Online at:
sales@GlobalTestSupply.com
E N G L I S H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvin Arnoux F07

  • Page 1 CLAMP-ON MULTIMETER  GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com E N G L I S H User Manual...
  • Page 2: Statement Of Compliance

    Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications.
  • Page 3: Table Of Contents

    1.2 Definition of Measurement Categories ........5 1.3 Receiving Your Shipment ............5 1.4 Ordering Information ..............5 1.4.1 Accessories and Replacement Parts ......5 2. PRODUCT FEATURES ..............6 2.1 Description ................6 2.2 Model F07 Callouts ..............7 2.3 Rotary Switch Functions ............8 2.4 Command Buttons ..............8 2.5 Hold Button Primary Functions ..........8 2.5.1 Display Lock ..............8 2.5.2 Preselecting MIN/MAX Mode ........8 2.5.3 Automatic Compensation for Lead Resistance ....9 2.5.4 Automatic Compensation of Current Measurement...
  • Page 4 2.10 Hz Button ................13 2.11 Button ................13 2.12 Liquid Crystal Display .............14 2.12.1 Digital Display .............14 2.12.2 Symbol Display ............14 2.13 Buzzer ..................15 3. SPECIFICATIONS................16 3.1 Electrical .................16 3.1.1 Voltage ( ) ..............16 3.1.2 Continuity ( ) .......... 17 3.1.3 Resistance (Ω) ............17 3.1.4 Semi-Conductor Test (...
  • Page 5 4.8 Temperature Measurement - (T°) ...........27 4.8.1 Without a Sensor ............27 4.8.2 With a Sensor .............27 4.9 Adapter Measurement - ( )..........28 4.9.1 Scale Factor Selection ..........28 4.9.2 Scale Factor Programming .........29 4.9.3 Implementation ............29 5. MAINTENANCE ................30 5.1 Changing the Battery ..............30 5.2 Cleaning ..................30 5.3 Storage ...................30 Repair and Calibration ................31 Technical and Sales Assistance ............31 Limited Warranty ...................32 Warranty Repairs ...................32 GlobalTestSupply...
  • Page 6: Introduction

    This symbol refers to a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted. In conformity with WEEE 2002/96/EC GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 7: Definition Of Measurement Categories

    Save the damaged packing container to substantiate your claim. Ordering Information Clamp-on Multimeter Model F07 ........Cat. #2129.54 Includes multimeter, 2 cables with probe tips, 1 K-type thermocouple adapter, 9V battery, soft carrying case and this user manual. 1.4.1 Accessories and Replacement Parts Replacement set of leads, red and black with probe tips ..Cat. #2118.92 Soft Carrying Pouch for Clamp-on Multimeters ....
  • Page 8: Product Features

    ● power auto-off ● MIN - MAX - PEAK value recording function ● correction of differences in DC measurement (DC zero) ● automatic compensation of measurement lead resistance (Ω zero) Compliance with IEC electrical safety standards and  CE markings Light and rugged construction for field use  “INRUSH” function, for measurement of motor starting  currents “Adapter” function, with direct reading via scale factor  programming. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 9: Model F07 Callouts

    Model F07 Callouts   Jaws Command Buttons  6-way Rotary Switch  Liquid Crystal Display GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 10: Rotary Switch Functions

    Short-press the HOLD button to freeze/lock the display. Press again to unlock. 2.5.2 Preselecting MIN/MAX Mode Short-press the HOLD button, then the MIN/MAX button to prese- lect the MIN/MAX mode. Press the HOLD button again to make the MIN/MAX mode effective. Use this function to preselect the MIN/MAX mode to prevent unwanted or mistaken integration of MIN/MAX values. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 11: Automatic Compensation For Lead Resistance

    Hold Button Secondary Functions (with rotary switch) 2.6.1 Disable Auto-off Function While pressing down the HOLD button, turn the rotary switch from the OFF position to the position. The unit emits a double beep, then the symbol flashes. The selected configuration is put into memory when the button is released (the symbol remains lit continuously). Automatic stop is reactivated when switch returns to OFF position. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 12: Activate The V-Live Function

    Yellow Button Primary Functions 2.7.1 Manual Selection of AC/DC Mode By default, the clamp switches to AC or DC mode automatically (AC/DC symbol flashes) for the A and V functions. When the mode is manually selected, the AC/DC symbol is fixed. Use a series of short presses on the yellow button to manually select AC/DC measurement, and to return to automatic mode. NOTE: Manual selection is not possible in MIN/MAX or HOLD mode, The selection of AC+DC mode for the adapter function is not possible either. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 13: Possible Selections In Continuity Function

    (40.0 by default). Adjustment is then possible from 1Ω to 40Ω by pressing the yellow button (short pressure: progression of 1Ω by 1Ω; press and hold: progression of 10Ω by 10Ω). Once the value is chosen, activate the rotary switch to memo- rize. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 14: Selecting °C Or °F As The Default Setting

    The unit emits a double beep, then all the segments of the digital display and the symbol flashes. The default configuration is set when the button is released (the display no longer flashes and the symbol disappears). The default configuration is: • Audio identification threshold: 40Ω • Auto-off: ON • V-Live function: none • Scale factor in adapter function: 1 • Unit for temperature measurement: not controlled GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 15: Com Sales@Globaltestsupply.com

    A short press displays the frequency of the measured signal, another press switches back to the previous value. This button is active only for the A functions. 2.11 Button Short pressure: Display backlight command. Automatic shutdown after 2 minutes. Held pressure: Display of estimated remaining battery power, in hours (except INRUSH and phase order functions). GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 16: 2.12 Liquid Crystal Display

    OL : Unsigned value range exceedance - - - - : Indeterminate value (middle segments) 2.12.2 Symbol Display Flashing: power limited to approximately 1 hour Steady: battery drained, operation and accuracy are no longer guaranteed Constant operation (no automatic shutdown) ON steady when the INRUSH function is selected Fixed: Continuity measurement Flashing: V-Live function selected HOLD Function active PEAK ON in V and A in MIN/MAX mode if the measurement of the peak value is selected MAX Indicates the display of a maximum value in MIN/MAX mode MIN Indicates the display of a minimum value in MIN/MAX mode GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 17: 2.13 Buzzer

    • 5 short and medium recurring sounds: automatic shutdown of the instrument • Continuous medium sound: measured continuity value lower than programmed threshold, short-circuit connection during semi- conductor test • Modulated medium continuous sound: value measured in volts, higher than 45V peak when the V-Live function is selected GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 18: Specifications

    **In AC if the value of the voltage measured is <0.15V the display indicates 0.00. MIN/MAX Mode: Accuracy: same as previous table +0.2% of Reading Capture Time: 100 ms typical PEAK Mode: Accuracy: same as previous table +2% of Reading Capture Time: 500 µs typical (2.5 ms max) Detection Threshold Accuracy (V-Live Mode): 45V peak ± 2V GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 19: Continuity

    MIN/MAX Mode: Accuracy: same as previous table +0.2% of Reading Capture Time: 100 ms typical 3.1.4 Semi-Conductor Test ( Display Range Measuring Range 0 to 3.199V Accuracy 1% of Reading + 2cts Resolution Measuring Current* 2mA to 4mA Overload Protection 500V or 750V or peak GlobalTestSupply *Per the voltage measured www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 20: Current

    **Below the triggering threshold, the display shows an indeterminate value (- - - -). In AC +DC mode, the GlobalTestSupply triggering threshold corresponds to the AC component (AC) of the signal. www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 21: Temperature (T°)

    In AC, the display shows OL above +3999. Range switchnig (400mV to 4V) is automatic. In AC, the lower limit of the measurement range is 5.0mV. MIN/MAX Mode: Accuracy: same as previous table +0.2% of Reading Capture Time: 100 ms typical GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 22: 3.1.10 Power Supply

    Charge life: 75 h or 25,000 x 10 s measurements Low Battery indicator: Flashing: Charge life < 1 h Fixed: Change battery Auto-off: 10 minutes with no action on the rotary switch or the buttons Mechanical Dimensions: 2.76 x 7.6 x 1.46" (70 x 193 x 37mm) Weight: 9.17 oz (260g) Clamp Tightening Capacity: ≤1.00" (≤26mm) Environmental 1. Reference Range Temperature: 2. Operating Range 3. Storage Range (without battery) Œ  Ž Ž Temperature in °C GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 23: Safety

    • Free fall 1m (test as per IEC 68-2-32) • Impacts: 0.5 J (test as per IEC 68-2-27) • Vibrations: 0.75mm (test as per IEC 68-2-6) Auto Power OFF (per UL94) • Housing V0; Jaws V0; Display window V2 GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 24: Variations In Operating Range

    40 dB (AC, AC+DC) <1ct 60 dB Rejection of common 0 to 600V/50Hz 0.07A/100V 0.1A/100V mode T° <1ct 60 dB Influence of external 0 to 400A/m 70 dB 60 dB magnetic field (50Hz) Number of moves 50,000 0.3% R 1% + 1ct opening of jaws GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 25: Typical Frequency Response Curves

    Frequency (Hz) - V (adp) = f (f) 10.00% 5.00% 0.00% -5.00% Specified limits -10.00% -15.00% -20.00% -25.00% 10000 Hz 100 Hz 10 Hz 1000 Hz Frequency (Hz) GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 26: Operation

    Trms, a repetitive beep of the buzzer indicates that the measured voltage is higher than the acceptable safety voltage (OL). Audio Continuity Test - 1. Connect the measurement cables to the terminals. 2. Set the rotary switch to the “ ” position. 3. Connect the unit to the circuit to be tested. The buzzer is contin- uously active as soon as contact is established (circuit closed) and if the resistance value measured is lower than the threshold value chosen by the programming (adjustable from 1 to 40Ω). GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com NOTE: Above 400Ω, the display indicates OL. Clamp-on Multimeter Model F07...
  • Page 27: Lead Resistance Compensation (Ω Zero)

    3. Connect the unit to the semi-conductor (junction) to be tested. • The measurement current moves from the “+” terminals to the “COM” terminal. It corresponds to the direct testing of the semi-conductor junction. Short-circuit junction: audio indication for a threshold <0.050V GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Cut or reversed junction (or threshold >3.2V): OL displayed Clamp-on Multimeter Model F07...
  • Page 28: Current Measurements - ( )

    ½, 1, 2½, 5 and 10 periods from the largest rms value computed and updated on ½ period. The applications are: • Measurement of motor start-up currents • Correct definition of fuses and circuit breakers (signal amplitude- time relationship) • Stress on components by current overload The field of application is limited to industrial frequencies (15Hz to 70Hz) GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 29: Implementation

    (the INT symbol is lit), which is the same as the ambient temperature after a sufficient thermal stabilization time. It can be expressed °C or °F: the unit is chosen with the yellow button. 4.8.2 With a Sensor 1. Connect the sensor (couple K) to the clamp terminals, observ- ing the polarity. 2. Place clamp where the temperature is to be measured. 3. Set the rotary switch to the “T°” position. The temperature dis- played is that of the sensor (EXT symbol is lit). It can be expressed GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com in °C or °F: the unit is chosen with the yellow button. Clamp-on Multimeter Model F07...
  • Page 30: Adapter Measurement

    100k 1mV/A 10mV/A 100mV/A 1000mV/A (1mV/mA) 10mV/mA 100mV/mA 100m The example given in Amperes (A) is valid for any other quantity: humidity (%HR), light (lux), speed (m/s), etc. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 31: Scale Factor Programming

    Display 10 m 100 m 10 k 100 k 2. To change the scale factor, press the yellow key successively until the required value is obtained. 3. Use the rotary switch to save this value. 4.9.3 Implementation 1. Connect the adapter to the clamp. 2. Program the scale factor if necessary (see §4.9.2). 3. Set the rotary switch to position “ ”. 4. Select the type of voltage using the yellow key, if necessary (AC or DC). GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 32: Maintenance

    3. Replace the used battery with a 9V battery (type LF22), observing the polarities. 4. Install the battery in its housing, then reattach the battery cover. Cleaning Disconnect the instrument from any source of electricity. • Use a soft cloth lightly dampened with soapy water. • Rinse with a damp cloth and then dry with a dry cloth. • Do not splash water directly on the clamp. • Do not use alcohol, solvents or hydrocarbons. • Make sure the gap between the jaws is kept clean and free from debris at all times, to help ensure accurate readings. Storage If the instrument is not used for a period of more than 60 days, remove the GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com battery and store it separately. Clamp-on Multimeter Model F07...
  • Page 33: Repair And Calibration

    Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship instruments to our Foxborough, MA address. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 34: Limited Warranty

    Ship To: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Clamp-on Multimeter Model F07...
  • Page 35 GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com...
  • Page 36 11/08 99-MAN 100268 v6 GlobalTestSupply Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Table of Contents