Technical Data - Record DFA 127 Operating Instructions Manual

Automatic swing door operator
Hide thumbs Also See for DFA 127:
Table of Contents

Advertisement

3

Technical Data

Dimensions:
Operating voltage:
Power consumption:
Max. torque:
Opening angle:
Time delay:
Opening speed:
Closing speed:
Noise emission
Environment conditions
Temperature range:
Humidity range:
3.1 Permissible door leaf weights and door widths
The curves are calculated using to the following formula:
Standard arms
Slide arms
Page 4 of 20
Operator 600 x 85 x 124 mm (w x h x d)
230V∼
Standby 13 W, rated power 67 W
50 Nm
Adjustable from 70° to 115°
Adjustable from 0 to 20 seconds
Adjustable from 3 to 20 seconds
Adjustable from 5 to 20 seconds
-18 dB
-15 to + 50°C
Up to 85% relative humidity, non bedewing
J = 1/3 × m × b
2
: J max. 65 kgm
2
: J max. 65 kgm
Rev. B 11/2006
2
Key : J = mass moment of inertia [
m = door leaf weight [kg]
b = door leaf width [m]
Operating instructions DFA 127 Full Power
2
]
kgm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents