Alarm Management; Alarm Input; Alarm Output; Stop Alarm Condition - ECOLINE TV7094 Installation Instructions Manual

Day/night speed dome camera / lcd-keyboard
Table of Contents

Advertisement

ALARM MANAGEMENT

ALARM INPUT

The speed dome camera is equipped with six alarm input connectors. These connectors
correspond to both preset positions and auto pan groups.
NOTE: To choose the correspondant funtion (auto pan group / preset position) go to the OSD
of the keyboard and set the function accordingly.
Once the alarm signal is detected the speed dome camera will automatically move to the
preset position or start up the auto pan group. In addition the alarm buzzer and the LED of the
EVENT RESET
button is activated
The keyboard's LCD displays:
The monitor picture displays the message „ALARM". The message disappears as soon as the
position of the dome camera is changed.
NOTE: By activating multiple alarm inputs at the same time the dome camera will move to
the position that is related to the latest activated alarm input.

ALARM OUTPUT

The alarm output (NO/NC) is activated accordingly to the alarm input.

STOP ALARM CONDITION

Stopping the alarm condition (and resetting the alarm output) can be done in two ways.
a) Manualyy by pressing the button
alarm buzzer
will turn off.
b) Automatically after the preset alarm time.
NOTE: Set the alarm time in the keyboard's OSD.
DEVICE
:
XXX
ALARM
INPUT
EVENT RESET
21