ECOLINE TV7094 Installation Instructions Manual

Day/night speed dome camera / lcd-keyboard

Advertisement

Quick Links

Day/Night Speed dome camera /
LCD-keyboard
INSTALLATION INSTRUCTIONS
TV7094
TV7091
1

Advertisement

Table of Contents
loading

Summary of Contents for ECOLINE TV7094

  • Page 1 Day/Night Speed dome camera / LCD-keyboard INSTALLATION INSTRUCTIONS TV7094 TV7091...
  • Page 2 To maintain this status and to guarantee safe operation, it is your obligation to observe these operating instructions! This ECOLINE speed dome camera is used in combination with video sources (cameras) and recording devices (VHS or digital recorders) for the purpose of property surveillance. It enables the user to build up a flexible and wide ranging surveillance.
  • Page 3 the instructions very carefully General: Improper or careless and follow the installation installation work may lead to instructions for lines and faults and poor image components precisely. quality. Therefore please read...
  • Page 4: Table Of Contents

    Content SCOPE OF DELIVERY..........................5 IN CASE OF OUTDOOR INSTALLATION OF THE SPEED DOME, USE AN OUTDOOR HOUSING..5 OVERVIEW ..............................7 SYMBOL DESCRIPTION ..........................7 COMPONENT AND STRUCTURE DESCRIPTION ..................8 CAMERA SETTING ............................9 TERMINAL FOOT CONNECTION, DATA LINE AND SIGNAL LINE REGULATION ........ 11 INSTALLATION OF THE SPEED DOME CAMERA..................
  • Page 5: Scope Of Delivery

    Scope of delivery Packaging ECOLINE speed dome camera Power unit with connection cable Installation guides In order to control the speed dome camera, use the keyboard (TV7091) In case of outdoor installation of the speed dome, use an outdoor housing.
  • Page 6 (TV7092) (TV7093)
  • Page 7: Overview

    Overview • Speedy response with 26 times continuous auto-focus zoom lens and 10 times Electronic Zoom • Auto Iris and Manual Iris Control • Advanced DSP Camera, including Auto White Balance, Backlight Compensation and Auto Iris Control. • 360° Continuous Pan Rotation. •...
  • Page 8: Component And Structure Description

    Component and structure description Elektronic Alarm input or output / Video input / Power input terminal Elektronic ID position setup Elektronic Embellish Cover Mechanic Machine housing Camera Transparent cover / Black housing module...
  • Page 9: Camera Setting

    Camera setting Connection of up to 127 Speed Dome SW1: ID number setting Cameras, each camera has its own ID number. Please setup each camera with its own ID number. Else the system is not able to DIP-Schalter differentiate between different camera modules.
  • Page 10 SW2: Protocol setup Setup DIP switch number Applied protocol #4 #3 #2 #1 Off Off Off Off YOKO Off Off Off On PELCO Off Off On Off Reserviert Off Off On On Reserviert * Speed dome automatically detects the type of PELCO Protocol. No switch settings are required to set D and P Protocols.
  • Page 11: Terminal Foot Connection, Data Line And Signal Line Regulation

    Terminal foot connection, data line and signal line regulation Video output Alarm input/output 10 ~1 Power 12VDC Connect the plug of a 12VDC,1.5A power source. Video output Video signal output of VCBS 1.0Vp-p 75Ohms BNC. Alarm input/ The speed dome camera is equipped with 6 external alarm output triggering inputs and 2 sets of alarm outputs (1 set NO and 1 set NC).
  • Page 12: Installation Of The Speed Dome Camera

    Installation of the speed dome camera In ceiling mount Flush mount...
  • Page 13 Description of the keyboard (10) (11) (12) System reset Press this button to reset and restart the system. Key buttons These buttons are used to select certain speed dome cameras and preset positions. Lens buttons These buttons are used to manually adjust the lens. ID-select This button is used to select a certain speed dome camera.
  • Page 14: Back Panel Terminals

    Back panel terminals Power 12VDC Connect a 12VDC, 1,5A power source. RS-485 terminal To connect the 2 wires communication control cable to the speed dome D+D- D+D- RJ-485 / RJ-11 Alternatively you can connect the dome via the RJ-11 connector. System installation The system supports connections of numerous Speed Dome Cameras or...
  • Page 15: Operation

    Operation System reset and first usage After connecting all necessary cables startup the system linking by following this proceedure. The same proceedure is nedded to reset the system: 1.Step: Press the button SYS RESET . ⎡ ⎤ SYSTEM LINKING? The LCD displays the following message: ⎢...
  • Page 16 The button is used to zoom in. Objects are displayed bigger. The ZOOM TELE angle of viewing becomes more and more narrow. The button is used to zoom out. Objects are displayed smaller. The ZOOM WIDE angle of viewing becomes wider.
  • Page 17: Keyboard Buttons

    Keyboard buttons SET PRESET is used to setup individual selected pregrogrammed positions, so called SET PRESET preset positions. To store a current position as preset position follow steps given below: 1. Step: Choose a speed dome camera in which you want to programm a preset position, e.g.
  • Page 18: Go Preset

    GO PRESET button is used to direct the speed dome camera to a prior stored preset GO PRESET position. To call a preset position follow the steps given below: 1. Step: Choose a speed dome camera in which you want to programm a preset position, e.g.
  • Page 19: Auto Focus

    Key in: 0 0 1 AUTO PAN ⎡ ⎤ DEVICE The keyboard’s LCD displays: ⎢ ⎥ ⎣ ⎦ AUTOPAN GROUP LED is lid. AUTO PAN Stop the auto pan function To stop the auto pan function simply press the button again.
  • Page 20 button enables the user to select the next higher (+) or lower (-) speed dome CH+/CH- ID number.
  • Page 21: Alarm Management

    ALARM MANAGEMENT ALARM INPUT The speed dome camera is equipped with six alarm input connectors. These connectors correspond to both preset positions and auto pan groups. NOTE: To choose the correspondant funtion (auto pan group / preset position) go to the OSD of the keyboard and set the function accordingly.
  • Page 22: Osd Operational Description

    OSD operational description The keyboard’s OSD allows the setup of the speed dome camera. The following table gives an overview about possible settings. Please follow the steps given below: 1. Step: Select a speed dome camera in which you want to change the settings, e.g. camera 1.
  • Page 24 IMAGE SET UP BRIGHTNESS 001 ~ 050 FLICKERLESS ON / OFF Please select „Off“ position SHARPNESS 001 ~ 016 MIRROR ON / OFF ALARM SET UP ALARM PIN 001 ~ 006 ALARM SWITCH ON / OFF ALARM TYPE GPO / RAP Alarm reaction GPO: Go to preset position RAP: Start AUTO PAN group...
  • Page 25: Simple Operational Reference Table

    Simple operational reference table Functions Method of of operation Restart system connection SYS RESET Manual pan and tilt Push the joystick in the required direction Enter ID number 0 0 1 ENTER Select dome camera CH+ CH- Lens control ZOOM TELE ZOOM WIDE Manual control (Auto focus LED is not lid) FOCUS NEAR...
  • Page 26: Connecting Pelco-Keyboard (Kbd200A/Kbd300A)

    Connecting PELCO-keyboard (KBD200A/KBD300A) Connect the RS-422 serial port (terminal TX +) from the control keyboard, to the Speed Dome Camera RS-485 serial port (terminal D +). And connect the RS-422 serial port (terminal TX -) from the control keyboard, to the Speed Dome Camera RS-485 serial port (terminal D -). Normal Display Mode Speed Dome Function PELCO Keyboard...
  • Page 28 Please take notice of the following OSD changes Shutter Speed 001~027 → 000~027 Iris Level 001~050 → 000~050 AGC Level 001~050 → 000~050 Red Data 001~050 → 000~050 Blue Data 001~050 → 000~050 WB Data 001~050 → 000~048 BRIGHTNESS 001~050 →...
  • Page 29: Trouble Shooting

    Trouble shooting Dear customer, our technical support is eager to support you with any kind of technical problem during installation, setup and usage of this product. Plese read this trouble shooting note befor you contact our technical support. The main problems can be often solved – Thank you! Error Things to be checked Speed dome does not show a picture on...
  • Page 30: Technical Data

    Technical data Mechanics • Manual Operation: Horizontal Rotational Speed 1° to150° Per Sec. • Vertical Rotational Speed 1° to 100° Per Sec. • Manual call on preset points: horizontal Rotational Speed 1° to 300° Per Sec. • Vertical Rotation Speed 1°...
  • Page 31 • Height 206.5mm • Diameter 145mm • Weight (Standard) 2.5Kg...

This manual is also suitable for:

Tv7091

Table of Contents