Hagstrom KE-USB36FS User Manual

Usb keyboard encoder

Advertisement

Quick Links

KE-USB36FS
USB Keyboard Encoder
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hagstrom KE-USB36FS

  • Page 1 KE-USB36FS USB Keyboard Encoder User Manual...
  • Page 2 Please take a few minutes to read this manual before using your KE-USB36FS. NOTICE: The KE-USB36FS product is designed for use by technically oriented computer users. When the KE-USB36FS is in use, your Computer’s signals and voltages are present on the unit.
  • Page 3: Table Of Contents

    CONTENTS Introduction to the KE-USB36FS Connection to the Computer Interfacing to the KE-USB36FS Input Header Keyboard Status Light Signals Interfacing to the KE-USB36FS Auxiliary Port Configuring the KE-USB36FS Multiple KE-USB36FS Units Appendix A - Specifications Appendix B - Operating Tips...
  • Page 4: Introduction To The Ke-Usb36Fs

    The KE-USB36FS Keyboard Encoder is a product designed to interface switches or other switching devices to a computer’s USB port. The KE-USB36FS appears as both a keyboard and a mouse to your computer system. The 36 inputs on the KE-USB36FS header may be programmed to emulate any key from a standard keyboard.
  • Page 5: Connection To The Computer

    Follow the default selections to load the standard drivers for the KE- USB36FS. The KE-USB36FS is powered directly from the USB port, so no external power is required. The KE-USB36FS is compatible with all operating systems which...
  • Page 6: Interfacing To The Ke-Usb36Fs Input Header

    Interfacing to the KE-USB36FS Input Header The KE-USB36FS features a 2x20 header for interface to your input devices. The input header is arranged with grounds on the end pins of the header, and the 36 inputs between them. The board is labeled near each header pin, designating the input number that the pin represents.
  • Page 7: Keyboard Status Light Signals

    KE-USB36FS. Note: The KE-USB36FS allows all of the inputs to be activated simultaneously. Keyboard Status Light Signals Keyboard status light drive is available with the KE-USB36FS. The unit provides a 6 pin header for connection of the Num Lock, Caps Lock, and Scroll Lock status LEDs.
  • Page 8: Interfacing To The Ke-Usb36Fs Auxiliary Port

    USB36FS for 5 volt operation only. Figure 7 - The KE-USB36FS Auxiliary Port Trackball inter- This interface face. The connector features 8 pins spaced at .100” centers. compatible with the most popular active or passive Trackballs and Spinners.
  • Page 9 Rotary-5. The supplied KE-USB36FS configuration program is used to enable the Rotary-5 function on the auxiliary port. Select the checkbox to enable the Rotary-5 functions in the KE-USB36FS configuration program. In this configuration, the KE-USB36FS delivers the required power to the Rotary-5 for operation.
  • Page 10 When the auxiliary port is used with a Relay-8 unit, this configuration allows for control of the eight relays on the Relay-8 through the use of a provided .dll. The disk supplied with the KE-USB36FS has a section which includes examples of integrating code into a program which controls the Relay-8 output states.
  • Page 11: Configuring The Ke-Usb36Fs

    Configuring the KE-USB36FS The KE-USB36FS is supplied with a utility program which allows quick and easy setup of the inputs on the unit. Run the KEUSB36FS. EXE utility program to start the configuration program. The menu for the program appears as shown below.
  • Page 12 Note that a Trackball need not be attached to emulate the mouse buttons. The KE-USB36FS runs as both the mouse and the keyboard at all times. If no Trackball device is connected to the...
  • Page 13 The computer keyboard settings dictate the repeat speed. Trackball Adustments When the KE-USB36FS Auxiliary port is used for a trackball, there are several option sthat may be selected with checkboxes shown on the KE-USB36FS configuration program screen. These options...
  • Page 14 Saving the Configuration Once the configuration has been created, it is recommended that the configuration be saved to disk. The KE-USB36FS program provides an option for saving the configuration as a custom disk file, so it may be recalled at a later time for loading or modification.
  • Page 15 Configurations saved at a prior time may be recalled by using the Open selection and choosing a file from the selection list. To save the configuration to the KE-USB36FS, select File, then . Be sure that the KE-USB36FS is connected to Write to KEUSB36FS the computer prior to this step.
  • Page 16: Multiple Ke-Usb36Fs Units

    Multiple KE-USB36FS Units Virtually any number of KE-USB36FS units may be attached to the same computer. The configuration program for the KE-USB36FS will recognize up to 4 units on a system and allow for them to be programmed individually. If multiple KE-USB36FS units are detected when writing a configu- ration to, or reading a configuration from a device, the program will display a list of the individual serial numbers of the units.
  • Page 17: Appendix A - Specifications

    Appendix A: Specifications 3.25 3.00 .125 .625 .625 Dia (4) Operating Voltage 5 Volts DC +5%, -13%, Supplied from USB port (Bus powered) Operating Current 100 ma Maximum Operating 0 to 70 Degrees C Temperature Input Header 2x20, with 36 individual inputs and 4 Ground connections.
  • Page 18: Appendix B: Operating Tips

    Appendix B: Operating Tips The KE-USB36FS is configured as 36 individual inputs, which are activated by shorting them to the common logic Ground provided on the header. Since these inputs are individual, they are completely separate, and cannot produce “ghosting” as in a matrix application.
  • Page 19: Appendix C - Ke-Usb36Fs Read/Write From Command Line

    Right Shift, Left and Right Alt, Left and Right Control, and Windows GUI keys, can be used in addition to the six key limitation. The KE-USB36FS has the option of repeating an input that is held on. If the input is selected to repeat, that input will count toward the six key limit.
  • Page 20: Accessories

    Accessories We offer several accessories to connect to your KE-USB36FS. KE-USBMM6 6 ft. Male/Male Type A to Type B USB Cable IOX36 Input Header to screw terminal breakout board. This product connects to the KE- USB36FS input header through a standard IDE cable (included).
  • Page 21 Accessories MTA100-8/5-36FF 8 position MTA connector to 5 position MTA style connector. Use to connect either a Rotary-5 or a Relay-8 unit to the KE-USB36FS Auxil- iary connector. 3 ft Standard Length. MTA100-5-36-FF 5 position MTA connector to 5 position MTA connector. Use to daisy chain a Relay-8 and Rotary-5 board together when using both with the KE-USB35FS and an MTA100-8/5-36FF.
  • Page 22: Custom Ke-Usb36Fs Options

    Custom KE-USB36FS Options We offer custom modifications to our standard KE-USB36FS unit to conform to your exact specifications. We can add special features such as matrix scanning, display interfaces, and alternative connectors, just to name a few of the options. Give us a call to discuss your custom requirements.
  • Page 23 Depending on the state in which you live, you may have additional rights. Great care has been taken during the assembly, testing, and burn-in of your KE-USB36FS to ensure its performance. If you have any questions, please send us an email or give us a call. Support is available Monday through Friday, 8:00 am to 5:00 pm (EST).
  • Page 24 HAGSTROM ELECTRONICS, INC. Toll Free 888-690-9080 Phone: (540) 465-4677 Fax: (540) 465-4678 Monday through Friday, 8:00 am to 5:00 pm (EST) sales@hagstromelectronics.com www.hagstromelectronics.com 1986 Junction Rd, Strasburg, VA 22657 Copyright © 2017 HAGSTROM ELECTRONICS, INC. V. 07.17...