Beckman Coulter Navios Instructions For Use Manual page 84

Flow cytometer
Table of Contents

Advertisement

Specifications
Software Specifications
Table 4.1 FCS 2.0 Keyword Information
FCS 2.0 Keyword
$PnV
$PROJ
$RUNNUMBER
$SMNO
$SRC
$SYS
$TOT
@ABSCALFACTOR
@ACQTIME
@ACQUISITIONPROTOCOLOFFSET
@BARCODE
@BASELINEOFFSET
@BLUELASERPOWER_END
@BLUELASERPOWER_START
@BLUELASERSHUTTER
@BLUETARGETPOWER
@BUILDNUMBER
@CAROUSEL
@CYTOLINKMULTIPLECLIENT
@CYTOMETERID
@Discriminator
@ELAPSEDTIME
@FILEGUID
@LOCATION
@PANEL
@PnADDRESS
@PnC
4-12
Key value
Voltage of sensor associated with parameter n.
Project name (from Workspace Preferences)
(See $SMNO) System defined run number, that is, a number which is incremented
each time the flow cytometer is used to acquire data.
System defined run number, that is, a number which is incremented each time the
flow cytometer is used to acquire data.
Sample Source (from Workspace preferences)
BCI
Total number of events acquired.
Defines the calibration factor of the beads used with this sample if Flow-Count or
similar absolute calibration particles are used.
Acquisition time from start to end of acquisition (excluding pause time).
Defines where in the LMD file the Runtime Protocol is stored, the value displayed is
number of bytes from start of file to the start of the protocol section.
Barcode read from the sample loader or "No Read" if nothing is read.
Default is 'OFF' any other means ON, that is, this sample was acquired using baseline
offset.
Blue laser power at end of acquisition.
Blue laser power at start of acquisition.
Blue laser shutter status.
Blue laser target power.
Software build number.
Carousel number read from the sample loader.
Indicates whether other Cytolink client was connected to CytoLink during acquisition
of the LMD file ("TRUE" or "FALSE").
The unique ID given to the flow cytometer by the user, for example: the flow
cytometer serial number.
Displays the discriminator detector and level. In the form: "Detector Name, Level".
The Level value corresponds to the setting value displayed in the Cytometer Control
screen.
Total elapsed time from start to end of acquisition (including acquisition and pause
time).
Unique 128 bit number identifying this file, changed every time the file is saved.
The address of the institute who owns the flow cytometer.
Name of the panel file used for acquisition of the sample.
Mutliplexor address of parameter n.
Calculation method for parameter n, 'ARITHMETIC' means use arithmetic method for
calculation. 'GEOMETRIC' means use of a geometric method for calculation. This
value may be overridden by analysis engine.
773232AH