Sign In
Upload
Manuals
Brands
Beckman Coulter Manuals
Measuring Instruments
COULTER LH 750 System
Beckman Coulter COULTER LH 750 System Manuals
Manuals and User Guides for Beckman Coulter COULTER LH 750 System. We have
2
Beckman Coulter COULTER LH 750 System manuals available for free PDF download: Instructions For Use Manual, Reference
Beckman Coulter COULTER LH 750 System Instructions For Use Manual (182 pages)
Hematology analyzer
Brand:
Beckman Coulter
| Category:
Measuring Instruments
| Size: 3.01 MB
Table of Contents
Warnings and Precautions
2
Revision Status
3
Table of Contents
5
Contents
6
Introduction
13
How to Use Your Coulter ® Lh 780 System Hard-Copy Manuals
13
About this Manual
14
Online Help System
14
Conventions
14
1 Controls and Indicators
15
Analyzer
15
Analyzer Screen and CRT Buttons
15
Diluter
16
Numeric Keypad
16
Numeric Keypad--0-9
17
Numeric Keypad--Alarm Reset
17
Numeric Keypad--CE
18
Numeric Keypad--CLEAR APERT
18
Numeric Keypad--DRAIN
19
Numeric Keypad--ENTER
19
Numeric Keypad--F
20
Numeric Keypad--ID
20
Numeric Keypad--POWER off
20
Numeric Keypad--POWER on
21
Numeric Keypad--PREMIX
21
Numeric Keypad--PRIME APERT
22
Numeric Keypad--RINSE
22
Numeric Keypad--SHUT down
23
Numeric Keypad--START up
23
Numeric Keypad--START/CONT
24
Numeric Keypad--STOP
25
Power Supply
26
Side/Front
26
Back
27
Power Supply Function Levels
27
Power Supply Function Status
28
Power Supply Adjustment Controls
28
Workstation
30
CD ROM Drive
30
3.5-Inch Diskette Drive
30
Power On/Off (Workstation)
31
Workstation Keyboard
31
Monitor and Volume Controls
32
Using Command Center
32
Process Type
33
Bar-Code ID Field
33
Status Area
34
Default Type
35
Last Message
35
Reviewing System Status
35
2 Startup
37
Logging Off/On the Workstation
37
Logging off
37
Logging on
37
Performing Daily Startup
37
Checking Instrument Operation
37
Setting up Analyzer Date and Time
38
Setting up Analyzer Date Format
38
Turn Pneumatics on
38
Checking Power Supply and Vacuum Level
39
Check Baths
39
Automatic Startup Cycles
40
Checking Daily Test Results
40
Checking Background Test Results
40
Checking HGB Voltage Test Results
41
Checking Instrument Setup
41
Checking Precision Test Results
41
Checking Ramp Test Results
42
Possible Startup Problems and Fixes
42
Running Controls
42
3 Quality Control
43
Quality Control Overview
43
Latron
43
Running Latex Control-Diff
43
Running Latex Control-Retic
45
Time
45
Running Latex Control-Diff and Retic
46
Series Cell Control and Retic-C
47
Cycling Controls
47
Results
47
Aspirate Control in Manual Mode
48
Reviewing Control Results
49
Control Codes and Flags
49
When a Control Is Outside Its Expected Ranges
50
When a Latex Control Is Outside Its Expected Ranges
51
Controls Window
51
Transmit, Print and Archive
52
Deleting Control Data
52
Adjusting Control Limits
53
Providing Comments for Quality Assurance
53
Performing NRBC Quality Control
53
Extended Qc
55
Overview
55
Extended QC - Random Error
56
Extended QC- Systematic Error
56
Extended QC- Total Error
57
Xb Analysis
58
Overview
58
Reviewing XB Results
58
Adding Comments to an XB Batch
59
XM Analysis Overview
59
Overview
59
Reporting
62
Reviewing XM Results
62
Adding Comments to an XM Batch
63
Participating in Iqap
63
IQAP Setup
63
IQAP Download Procedure
63
Troubleshooting
64
PARTICIPATING in Eiqap
64
Enroll in Eiqap
64
Data Submission for Eiqap
64
4 Run Samples
67
Collecting Whole Blood Specimens
67
Storing Specimens
67
Venipuncture Specimens
67
Identifying Samples Overview
68
Automatic Aspiration Mode
68
Manual Aspiration Mode
68
Using the Predilute Mode
68
Setting up Identifiers
69
Universal Tube Processing
69
Overview
69
Using Bar-Code Labels
70
Labeling Requirements-Tubes Without Adapters or Clips
70
Labeling Requirements-Tubes with Sleeve Adapters
71
Labeling Requirements-Tubes with Cassette Clips
72
Clips
73
Cassette Handling
74
Cleaning the
74
LOADING the Using Cassette
75
Clips
75
Installing the Cassette
76
Using Handheld
77
Scanner
78
Setting up Bar-Code
78
Cycling Samples in Automatic Aspiration
79
Cycling Samples in Manual Aspiration
79
Mode
80
Changing the Number of Aspirations Per
81
Changing Test
81
Enabling/Disabling Blood
82
Configuration
82
5 Reviewing Data
83
Reviewing Sample
83
Results & Graphics Overview
83
Reviewing 2D
85
Enlarged View
85
What to Look for
85
Reviewing 3D
86
Retrieving Data
87
Changing the Minimizing the
87
What to Look for
88
Editing Sample
88
Reviewing Histograms
88
Reviewing Patient
89
Processing Results
89
Flagging
89
Rules for Flagging Results
90
8 Setup,8-1
90
Overview
90
Flags
92
Codes
94
Suspect Messages
95
5.12 Definitive Messages
96
Auto Validation Overview
97
6 Shutdown
103
Power On/Off Overview
103
Workstation
103
Analyzer/Diluter
103
Power Supply
104
Performing Daily Shutdown
104
Performing Extended Shutdown and Restart
104
Shutdown
104
Restart
104
Shutting down the Workstation
105
Resetting the Workstation
106
Using the Command Center
106
Using the Keyboard
106
7 Database and todo List
107
Database & todo Window
107
Columns You May Not Understand
107
Finding and Sorting
107
Selecting
107
Transmitting, Printing and Archiving
108
Other Actions
108
Common Functions (Overview)
108
Transmitting Results
108
Printing Reports
108
Archiving Data
109
Deleting Data
109
Deleting Patient Data
109
Deleting Sample Information
109
Printing
110
What Prints When You Select
110
Archiving
112
Formatting a CD for Direct Archiving
112
Archiving to a CD
112
Reviewing Archived Information
113
Saving Sample Results
114
Adding a Sample Request to the todo List
115
Adding a Test to an Existing Set of Sample Results
115
Database Overview
116
How Overwriting and Database Storage Work for Sample Results
116
Setting up Autosequencing
117
RANDOM ACCESS Random Access
118
Overview
119
Results of a Search
120
Name
121
Information
122
Setup
123
Information
124
Values
126
Information
127
Controls
128
Analysis
129
Analysis
130
Controls
131
Identifier
132
Range
133
8.13 Setting up Reporting Units
134
Manually Setting up Controls in Units Other than US1 or US2
135
8.14 Setting up Flagging Limits
136
Flagging Preferences
137
Defining Definitive Messages
138
Editing Existing Flagging Limits
138
8.15 Setting up Rules for Flagging Sample Results
139
Defining Delta Check Criteria
140
Defining Reflex Manager Criteria
141
Setting up the Rule Environment
141
8.16 Setting up the RBC Histogram Normal Range
142
8.17 Setting up Reports
143
Show Last Name before First Name
143
8.18 Setting up Institution Details
144
8.19 Setting up Lis / His Communications
144
Setting up Auto Validation
145
Sending LH
148
8.20 Changing an Instrument Name
148
8.21 Reviewing Workstation Settings
148
8.22 Setting up User Access Levels
149
Changing Your Password
149
8.23 Changing Physician List
151
Adding to the List
151
Deleting from the List
151
Editing the List
151
8.24 Changing Location List
152
Adding to the List
152
Editing the List
152
Deleting from the List
153
8.25 Setting up Database Storage Limits
153
Setting up Screen Saver
153
Setting up Colors
154
Setting up Date and Time
154
Setting up a New Printer
155
Setting up Your Default Printer
155
8.26 Run Configuration Window
156
Changing Your Default Printout Format
157
Changing Your Default Report Layout
157
Setting up Which Results to Print Automatically
157
Setting up Which Results to Transmit Automatically
158
Setting up When to Make a Slide
159
Turning Autocollation OFF/ON
160
Specifying Default Control Lot Numbers
161
Changing the Active Printer
162
COULTER Tubes
169
Kabe
170
Ldm
171
Workstation
172
Workstation
173
Trademarks
181
Advertisement
Beckman Coulter COULTER LH 750 System Reference (120 pages)
Brand:
Beckman Coulter
| Category:
Medical Equipment
| Size: 2.34 MB
Table of Contents
Warnings and Precautions
2
Revision Status
3
Table of Contents
5
Contents
6
Introduction
13
How to Use Your Coulter Lh 750 Series System Hard-Copy Manuals
13
About this Manual
14
Online Help System
14
Conventions
14
1 Use and Function
15
Intended Use
15
Indications for Use
15
Parameters
16
Quality Control (Qc)
17
Method History
17
Development
17
Corrected WBC Counts
18
Hemoglobinometry
18
Differential Measurement
18
Volume Analysis
18
Corrected WBC
18
Conductivity Analysis
19
Light Scatter Analysis
19
Reticulocyte (Retic) Analysis
19
Illustration of the Ten Light Scatter Regions
19
NRBC Enumeration
20
NRBC Signature Position on Differential Dataplot
20
NRBC Location on WBC Histogram
20
COULTER Intellikinetics Application
21
XB Analysis
21
XM Analysis
21
Extended QC
21
System Components
22
Power Supply
22
Diluter
22
Analyzer
22
LH Workstation
22
Handheld Scanner
22
Hardware Options
23
Graphic/Laser Printer
23
LH Slidemaker
23
LH Slidestainer
23
Controls and Calibrator
23
Controls
23
Calibrator
23
Reagents
23
Diluent
24
CBC Lytic Reagent
24
LH Series PAK Reagent System
24
The LH Series RETIC PAK Reagent Kit
24
Cleaners
25
Material Safety Data Sheets (Msds)
25
2 Installation
27
General
27
Special Requirements: Hardware
27
Space and Accessibility
27
Space for Tower-Type Computers
27
Electrical Input
28
Space for Small Form Factor (SFF)-Type Computers
28
Ambient Temperature and Humidity
29
Air Conditioning
29
Ventilation
29
Drainage
29
Interunit Connections
30
Power and Signal Cables
30
Changing 9-Pin and 25-Pin Connectors
30
Rear of Instrument and Accessories with DB-25 Pin for Tower-Type Computers
30
Pneumatic/Hydraulic Tubing Connections
31
Rear of Instrument with DB 9-Pin Connector
31
Pneumatic/Hydraulic Connections
32
Description of Pneumatic/Hydraulic Connections
32
3 Operation Principles
33
Coulter Method
33
CBC Analysis
33
Differential Analysis
33
Coulter Method of Counting and Sizing
33
Effect of Reagents
34
Reticulocyte Analysis
34
Automatic Aspiration Mode
34
Loading Specimens
34
Transporting Cassettes
34
Transport System
35
Aspiration
36
Delivery
36
Cbc
36
Differential (Diff)
36
Reticulocyte (Retic)
37
CBC Sensing System
38
CBC Analysis in the Baths
38
Diff and Retic Multiparameter Sensing System
38
Triple Transducer Module with Protective Housing
39
Backwash and Rinse
40
Manual Aspiration Mode
40
Triple Transducer Module with Protective Housing Cut Away
40
Counting and Sizing
41
Red and White Blood Cell Counting
41
Coincidence Correction
42
Voting
42
Pulse Editing
42
Sweep Flow
42
RBC Size Distribution
43
Platelet Method
43
Measurement of Hemoglobin Concentration
44
Dataplot Development
45
Two-Dimensional (2D) Dataplots
45
Three-Dimensional (3D) Dataplots
45
Parameters and Their Derivation
46
Summary of Parameter Derivations
46
Measured Directly
46
Derived from RBC or Plt Histogram
46
Derived from WBC Histogram
47
Calculated
47
White Blood Cell (WBC) Count
47
Red Blood Cell (RBC)
47
Hemoglobin (Hgb) Concentration
47
Mean Corpuscular Volume (MCV)
48
Hematocrit (Hct)
48
Mean Corpuscular Hemoglobin (MCH)
48
Mean Corpuscular Hemoglobin Concentration (MCHC)
48
Red Cell Distribution Width (RDW)
48
Platelet (Plt) Count
48
Mean Platelet Volume (MPV)
48
NRBC % (Nucleated Red Blood Cells)
48
Differential (Diff)
49
Diff Percentages (DIFF%)
49
Diff Absolute Numbers (DIFF#)
49
Reticulocyte (Retic) Parameters
50
Retic Percent (RET%)
50
Retic Absolute Number (RET#)
50
Immature Reticulocyte Fraction (IRF)
50
Mean Reticulocyte Volume (MRV)
50
Xb Analysis
51
Adjusting Initial XB Target Values
52
XM Analysis
53
Extended QC
53
Effect of Directly-Measured Parameters on the Red Cell Indices
53
4 Specifications/Characteristics
55
Physical Specifications
55
Dimensions
55
Power
55
Input
55
Consumption
55
PERFORMANCE SPECIFICATIONS--LH 700 Series
55
Precision
55
Within-Run Precision
55
Accuracy
56
Accuracy Qualification
56
Accuracy, CBC
56
Within-Run Precision
56
Accuracy, Reticulocyte
57
Linearity
57
Accuracy Tolerance Limits, WBC Differential
57
Accuracy, Reticulocyte, Using a Predicate Hematology Analyzer
57
Background
58
Carryover
58
Operating and Reportable Ranges
58
Linearity Limits
58
Mode-To-Mode Comparison
59
Performance Characteristics
59
Operating and Reportable Ranges
59
CBC Sample Stability, Cold Temperature
60
CBC Sample Stability, Room Temperature
60
DIFF% Sample Stability, Cold Temperature
60
DIFF% Sample Stability, Room Temperature
60
Sample Stability
60
DIFF# Sample Stability, Cold Temperature
61
DIFF# Sample Stability, Room Temperature
61
RETIC Sample Stability, Room Temperature
61
NRBC Sample Stability, Cold Temperature
62
NRBC Sample Stability, Room Temperature
62
RETIC Sample Stability, Cold Temperature
62
WBC Differential Flagging Stability
62
Differential Suspect Flagging at Cold Temperature
63
Differential Suspect Flagging at Room Temperature
63
MCV Accuracy Characteristics
63
MCV Performance Characteristics
63
NRBC Imprecision Characteristics,Paired Sample Analysis - Replicate 1 Vs
63
NRBC Paired Sample Imprecision
63
NRBC Accuracy Characteristics
64
NRBC Accuracy Characteristics, Compared Samples
64
Platelet Accuracy Characteristics
64
Normal Population Study
64
Plt Accuracy Characteristics Vs ICSH/ISLH Platelet Method
64
Humidity
65
Temperature
65
Reference Ranges
64
Storing Specimens
65
Sample Type
66
Recommended Anticoagulant
66
Sample Volume Aspirated
66
Sampling Modes
66
Aspiration
66
Test/Cycle
66
Throughput, Automatic Mode
66
Waste
66
Calibration Stability
67
Known Interfering Substances
67
Cbc
67
Nrbc
68
Differential
68
Reticulocytes
68
LH Workstation Storage
67
Pneumatic Supplies (Internally Regulated)
67
Bar-Code Symbology Overview
68
Character Set
69
Symbology Type
69
Fixed or Variable Length
69
Self-Checking
69
Start Code, Stop Code
69
Check Character, Checksum Algorithm
69
Quiet Zone, Quiet Area
69
BAR CODES and the LH 700 Series
70
Checksum Algorithm
70
Bar-Code Symbologies Supported by the LH 700 Series
70
Interleaved 2-Of-5
70
Code 39 (also Called 3-Of-9 Code)
70
Codabar
71
Code 128/USS 128
71
Bar-Code Tips
71
Bar-Code Label Specifications
72
General
72
Optical Characteristics at 880 Nm ±10% and 633 Nm ±10
72
Printing Method
72
Label Thickness
72
NE/WE Ratio
72
Label Dimensions and Data
73
Bar-Code Label Specifications
73
Acceptable Bar Codes
74
Extended Digit Bar Code
74
Checksum Algorithm
75
Interleaved 2-Of-5
75
Codabar
76
Codabar Character Value Table
76
NW7 Decoding
77
NW 7 Character Value Table
77
Code 39 Bar Code
79
Code 39 Character Value Table
79
Code 128
80
5 Hazards
85
Laser Safety
85
Radiation Hazards
85
Laser Warning Labels
85
Laser Warning Label, Protective Housing Cut Away
86
Bar-Code Reader
87
Laser Warning Label Locations, Protective Housing on
87
Bar-Code Reader Laser Warning Label Location, Protective Housing Cut Away
87
Bar-Code Reader Laser Warning Label Location, Protective Housing on
88
Handheld Scanner
89
Disposal of Electrical Instrumentation
89
Advertisement
Related Products
Beckman Coulter Cell Lab Quanta SC
Beckman Coulter LH 780
Beckman Coulter Optima LE-80K
Beckman Coulter Coulter LH 700 Series
Beckman Coulter Optima L-100K
Beckman Coulter Optima L-90K
Beckman Coulter AU2700
Beckman Coulter AU5800
Beckman Coulter CEQ 8000 series
Beckman Coulter Cytomics FC 500
Beckman Coulter Categories
Laboratory Equipment
Measuring Instruments
Medical Equipment
Desktop
Cash Counter
More Beckman Coulter Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL