Display
Backwash 1
00,0
Brine/Rinse
09.0
Backwash 2
02,0
Salt lbs.
01,5
(Salt kg 00,7)
Turbine Test
No
Reg. Tonight
Hayır
RO Comp?
No
When you press the P button at "RO Comp?" the values are saved, and the controller returns to Normal operating mode.
Warning: When iron and/or manganese is present in the water supply, do not use potassium chloride as a regenerant. Iron and/or manganese
bacteria may develop and foul the conditioning media and may void the warranty.
Meaning
Number of minutes the first
backwash cycle lasts
Number of minutes the
brine and slow rinse cycle
lasts
Number of minutes the
second backwash cycle lasts
Amount of salt set to be
used in each regeneration to
achieve the capacity setting
Used by qualified personnel
for diagnostic purposes
Sets the appliance to
regenerate tonight
Used when an RO system is
also installed
Possible Values
00.0 to 99.9
00.0 to 99.9
00.0 to 99.9
00.0 to 99.9 lb (kg)
No or Yes
No or Yes
No or Yes
Comments
Set to the nearest tenth of
a minute
Set to the nearest tenth of
a minute
Set to the nearest tenth of
a minute
Set to the nearest tenth
WARNING: Do not
engage this feature
If set to Yes, it will force a regeneration
at the next set regeneration time (such
as 02:00 a.m.). After the regeneration,
the value will be set to No
If set to Yes, the capacity will be
adjusted slightly to compensate
water use from an RO system
TR 27